Chapter 8: Troubleshooting
233
Logical Drive Quick
Initialization Stopped
User aborted Quick Initialization. Normal.
Logical Drive Percent
Completed
Progress in percent of synchronizing or rebuilding a
logical drive. Normal
Enclosure Notification
Enclosure Power Down
Power switched OFF. Turn power ON.
Enclosure Power Up
Power is ON. Normal.
Enclosure Unknown Error Unspecified problem with the Controller. If this
message appears frequently, note any malfunctions
and contact Technical Support.
Enclosure Over
Temperature
Click on Enclosure1 in WebPAM to identify location of
overheat condition. Verify that there is ample space
around the enclosure. Check that all fans are running
and airflow is not obstructed. Correct any problems.
Enclosure Fan Stop
Click on Enclosure1 in WebPAM to identify failed fan.
Replace as needed.
Enclosure 3.3 Volt Range Go to Controller management > Enclosure
management > Voltage in CLU.
Or click on Enclosure1 in WebPAM to check power
supply status. Replace as needed.
Enclosure 5 Volt Range
Enclosure 12 Volt Range
Battery Temperature Rise Click on Enclosure1 in WebPAM to check for
overheat condition. Correct any problems.
Battery Temperature
Dropped
Normal.
Battery Capacity below
threshold
Replace Battery.
Battery Capacity Normal
Normal.
Battery Discharging
Could be a SEP problem. If this message appears
repeatedly, contact Technical Support.
Battery Maintenance
Mode
Normal.
Battery life ended
Replace Battery.
Event
Action