Chapter 8: Troubleshooting
235
With a Hot Spare Drive
After the disk array rebuilds itself using the hot spare:
1.
Replace the failed drive.
2.
Check the automatic rebuild and hot spare policy to be sure your disk
array(s) recognize(s) the new drive as a hot spare.
Without a Hot Spare Drive
If no hot spare drive is available, the VTrak will not rebuild the disk array and it
will remain Critical.
When you install a replacement disk drive into the enclosure, the disk array will
automatically rebuild the information and data on the newly installed disk drive if
Automatic Rebuild option is enabled.
To enable Automatic Rebuild and set Hot Spare Policy, see page 119 (WebPAM)
or page 168 (CLU).
Enclosure Problems
WebPAM displays red circles
in Tree View to identify components that need
attention.
Important
If your replacement disk drive was formerly part of a different disk
array, use the CLU to wipe the reserve sector on the replacement
disk drive. See page 156.