Chapter 3: Setup
59
SMART check: enabled
Initialization: full
Create Logical Drive now(y/n)?>
y
4.
If you agree with the specifications, press Y and Enter.
If you disagree, press N and Enter. Then select
Create New Disk Array
(below) and input your own settings.
This completes disk array creation. Go on to logical drive creation.
Create a Disk Array Manually
Use this feature to manually build a logical drive to meet your own requirements
or to use less than the full number of available disk drives. See page 214 for a
discussion of RAID Levels, the number of drives each supports and an
explanation of the available options.
1.
From the Main menu, press 3 and Enter to access Disk Array Management.
2.
Press 2 and Enter to access the Create New Disk Array.
**************Define New Logical Drive**************
Total 8 Physical Drives
*********Physical Drives Selection*********
ID
Name
Capacity
----------------------------------------------------------
1
Maxtor 5A250J0
251 GB
3
WDC WD2000JB-00FUA0
200 GB
4
WDC WD2000JB-00FUA0
200 GB
7
ST380013AS
80 GB
9
WDC WD1200JD-00FYB0
120 GB
11
ST380013AS
80 GB
12
WDC WD1200JD-00FYB0
120 GB
15
Maxtor 6Y080M0
82 GB
Enter Physical Drive IDs and/or ID ranges
separated by commas. For example: 1,5,8-15.
Press R to continue after you have finished
selecting Physical Drives.
Your input?>
1,3,4,5,9
3.
Choose the physical drives for your logical drive and press Enter.
*********Physical Drives Selection*********
ID
Name
Capacity
----------------------------------------------------------