Cage Nut Spacing
If necessary, unscrew the rack post fasteners to enable the latching mechanism to
engage. Screw the rack post fasteners back into the proper holes.
g.
Use a level to make sure that the rails are aligned properly.
h.
Follow these steps for the other outer rail.
CAUTION
Always install the top cover onto the enclosure before
installing the chassis into a rack. Not having the top cover
installed may damage the alignment brackets.
Step 5 :
Install the rail mounting hardware, starting with the uppermost rack
mounting hole of the 4U space on the front of the rack.
CMA Standard:
a.
Install one cagenut at the uppermost
mounting hole of the 4U space that the enclosure
will occupy.
b.
If the VTrak J5960 will be installed in a rack
for shipping purposes, install four more M5 cage
nuts in the holes 3-6 of the 4U space. These
will receive the M5 x 12mm T15 Flat Head Torx
screws that secure the enclosure to the rack with
the shipping bracket.