enclosure
Syntax
enclosure [option] [sub-option] <argument>
Summary
Used to list enclosure related information. This is also used to reboot a controller or the VTrak J5000 enclosure
and to make enclosure settings including physical drive zone configuration.
See
for a description of the zone configuration options for physical drives.
Options
-l
Display enclosure information (default)
-m
Modify enclosure settings
Sub-options
-r <option>
Restart a controller, shutdown or restart the system.
<option> = 1: Restart the current controller.
<option> = 2: Restart the system.
<option> = 3: Restart the primary controller.
<option> = 4: Shutdown the system.
-t <enable>
Enable or disable thermal management.
<enable> = 0: Disable thermal management.
<enable> = 1: Enable thermal management.
-z <zoning config>
Set zoning configuration for physical drives.
<zoning config>
= 0: No zoning.
<zoning config> = 1: Zone configuration 1.
<zoning config> = 2: Zone configuration 2.
<zoning config> = 3: Zone configuration 3.
-a <allow>
Allow system shutdown on critical temperature.
<allow> = 0: System shutdown is not allowed.
<allow> = 1: Allow system shutdown.
-c <sensor_id><threshold_value> Update the critical threshold value for different enclosure sensors.
IOM critical threshold value = 68 ~ 72
ENC critical threshold value = 57 ~ 61
PSU critical threshold value = 57 ~ 61
47
12G SAS JBOD
User Guide