Promix-SM112
3
The pusher is located in the same casing as the lock, which allows not to mount a handle on
the door. If necessary, positions of the lock and the pusher inside the casing can be
interchanged; to do this, screw out the screw on the back side of the lock (may be hidden under
the sticker) and remove the metal base of the lock.
As voltage is applied, the lock will become unlocked, but the door will remain closed. To open
the door, press on it, then the lock, with its built-in pusher, will push and open the door slightly. If
the door was not pressed upon, then, after de-energizing, the lock will become blocked and the
door will remain locked.
5.
TECHNICAL DATA
5.1
TECHNICAL DATA
Modification
Promix-SM112.10
Version
normally closed
DC supply voltage U, V
12±2
Current consumed, А
0.1 (at 12V)
Supply pulse duration (not more
than), s
not rated.
Minimum pause between
pulses, s
not rated.
Lock weight (not more than), kg
0.17
Holding force (not less than), kg
150
Power wire length, m
0.1
Allowable thickness of door glass,
mm
4-8
3 holes