background image

Promix-SM132

 

 

2

 

4.

 

DESIGN AND PRINCIPLE OF OPERATION 

Locks  are  manufactured  with  a  normally-closed  design  (hereinafter  referred  to  as  NC).  NC 

lock  is  in  the  closed  state  when  no  voltage  is  supplied  and  in  the  open  state  when  power  is 
supplied to the lock. 

 

 
 

 

 

 

5. TECHNICAL DATA

 

5.1 OPERATING CONDITIONS 

The  lock  operation  environment  must  be  explosion-safe,  free  of  current-conducting  dust  or 

gases  that  cause  metal  corrosion  and  destroying  insulation  of  current  conductors  and  electric 
elements,  free  of  current-carrying  dust  or  water  vapor,  and  preventing  ingress  of  water,  steam, 
fuel and lubricants. 

Climatic operating conditions: У3.1 as per GOST 15150-69 with extended temperature range: 

 Ambient temperature: -30 to +50 

°С; 

 Relative air humidity: not higher than 98 % at 25 

°С or lower temperatures without moisture 

condensation and hoar-frost formation; 

 Installation indoors or outdoors excluding ingress of moisture, dust, dirt, etc. inside the lock. 

5.2 TECHNICAL DATA 

Modification 

Promix-SM132.10 

Design 

normally closed 

DC supply voltage U, V 

12±2 

Current consumed, А 

0.1 (at 12V) 

Availability of sensors 

Supply pulse width (max.), s 

not rated 

Fig. 2. Promix-SM.132 lock overall and mounting 

dimensions 

Fig. 1. Promix-AD.DB.26 latch overall and mounting 

dimensions 

Summary of Contents for Promix-SM132 Series

Page 1: ...by means of switches buttons or controllers of access monitoring and control systems audio and video intercoms code panels or other devices 2 LABELING The label attached to the lock body contains the following information 1 Lock model 2 Nominal supply voltage 3 Nominal consumed current 4 Date of manufacture and QCD mark 5 Identification number 6 Manufacturer s website Promix SM132 10 Supply voltag...

Page 2: ... or water vapor and preventing ingress of water steam fuel and lubricants Climatic operating conditions У3 1 as per GOST 15150 69 with extended temperature range Ambient temperature 30 to 50 С Relative air humidity not higher than 98 at 25 С or lower temperatures without moisture condensation and hoar frost formation Installation indoors or outdoors excluding ingress of moisture dust dirt etc insi...

Page 3: ...locking power For this purpose a controller control board or a switch button is generally used The controller is mounted in accordance with its certificate Connect the lock power wires adhering to the following polarity White positive pole of the power supply Black negative pole of the power supply Reverse voltage supply does not ensure lock operability but it does not cause its failure Example of...

Page 4: ...e latch nut A large clearance between the door and the base as the door is closed the latch stops against the inside of the lock The lock does not block the latch Check the distance between the latch and the lock if necessary increase the latch length 9 MAINTENANCE Maintenance of the lock is performed at least once every two months and includes Visual inspection of the lock to check the reliabilit...

Page 5: ...s for human life and health or for the environment disposal after its service life is performed without taking any special measures for environment protection 13 WARRANTY LIABILITIES The manufacturer ETC PROMIX LLC warrants conformity of Promix SM420 locks to requirements of current Technical Specifications provided that transportation storage installation and operation rules established in this M...

Page 6: ...y was manufactured and accepted in compliance with Specifications obligatory requirements of state standards and current technical documentation recognized as fit for operation and packed by ETC PROMIX LLC Engineering and Production Center PROMIX LLC Russia 214030 Smolensk Krasninskoe sh 35 lit A Phone 4812 619 330 www promix center com facebook com promixcenter mail promix center com ...