background image

Promix-SM213

 

 

9

 

 

It is prohibited to use silicone grease and WD-40.

 

The  warranted  operation  period  is  12  months  from  the  date  of  sale  but  not 
longer than 18 months from the day of acceptance by the manufacturer’s QCD.

 

Faulty  products  are  accepted  for  repair  only  together  with  the  latch,  on  the 
obligatory condition that factory labels are retained on the product body.

 

 Then sink the catch and lubricate inner walls of the body on the side of the catch. Replace the 

protective film removed earlier, and mount the lock on the door. 

10.

 

STORAGE AND TRANSPORTATION

 

Until putting into operation, the locks must be stored in the manufacturer’s packing, in rooms 

with an ambient temperature 

of -

30 to +50 °С

 

and a relative humidity not higher than 98% at 25º 

С in compliance with storage conditions as per GOST 15150-69. 

Locks transportation conditions must comply with group C as per GOST 23216-78 in terms of 

exposure to mechanical factors, and Ж2 as per GOST 15150-69 in terms of exposure to climatic 
factors. 

11.

 

SAFETY REQUIREMENTS

 

The design of the locks ensures safety of personnel involved in mounting and maintenance. 
Due to low DC supply voltage, the products correspond to class III as per ГОСТ 12.2.007.0-

75 and are electrically safe. 

Fire safety of the locks is ensured by use of non-combustible or hardly combustible materials, 

and low supply voltage. 

12.

 

DISPOSAL

 

The product is not hazardous for human life and health or for the environment; disposal after 

its service life is performed without taking any special measures for environment protection. 

13.

 

WARRANTY LIABILITIES

 

The  manufacturer,  ETC  PROMIX  LLC,  warrants  conformity  of  Promix-SM213  locks  to 

requirements of current Technical Specifications provided that transportation, storage, installation 
and operation rules established in this Manual are followed. 

Within the period of warranty, ETC PROMIX LLC undertakes to repair defective products free 

of charge. Expenses for transporting the product to the place of repair and back will be borne by 
the Buyer. 

Warranty liabilities do not cover any defects and damages caused by: 

 

Improper maintenance by the Buyer; 

 

Use of the product under conditions that do not comply with the operation requirements; 

 

Mechanical damages or disassembly of the products by the Buyer; 

 

Non-observance of the transportation and storage rules. 

On expiration of the warranty service period, the manufacturer provides after-warranty service 

on a contractual basis. 

Summary of Contents for Promix-SM213

Page 1: ... audio and video intercoms code panels or other devices The lock design and mounting method allow them to be installed on practically any door types 2 LABELING The label stuck to the lock body contains the following information 1 Lock model 2 Patent number 3 Nominal supply voltage 4 Nominal consumed current 5 Date of manufacture and QCD mark 6 Identification number 7 Manufacturer s website For the...

Page 2: ... door lock As voltage is supplied for NO lock or voltage is removed for NC lock the lock catch is block and does not permit the door opening As voltage is removed for NO lock or supplied for NC lock the lock catch is deblocked and as the door is opened is folded into the lock body 5 TECHNICAL DATA 5 1 OPERATING CONDITIONS The environment of the lock must be explosion safe free of current conductin...

Page 3: ... of glazed frost 5 2 TECHNICAL DATA Modification Promix SM213 00 Promix SM213 01 Promix SM213 11 Promix SM213 10 Version normally opened normally closed DC supply voltage U V 12 2 24 2 12 2 Current consumed А 100 0 1 at 12V 35 at 24V 75 at 24V 160 0 1 at 12V Supply pulse duration not more than s not rated 120 at 23 26V 120 at 11 14V Minimum pause between pulses s not rated 120 Holding force not le...

Page 4: ...door leaf During mounting a clearance of 1 8 mm must be provided between the locking plate and the fastening plate of the lock Meeting this condition guarantees a door holding force of 300 kg and a smooth operation of the door without wedging up It is necessary to provide a clearance between the catch and the locking plate in the closed state of the door Example of the lock installation in a pipe ...

Page 5: ...Promix SM213 5 Example of the lock installation in the door frame of a wooden door Example of the lock installation in the leaf of a metal door Door Door Door Door Locking plate Locking plate ...

Page 6: ...ition The sticker covers an opening for water drain from the lock Remove white protective film from the locking plate and the lock Example of the lock installation in the door frame of a plastic door Example of the lock installation in the leaf of a wooden door For mounting the lock drill 4 holes 2 2 5 mm in diameter for self tapping screws and the locking plate 30 32 mm in diameter for lock mount...

Page 7: ... organization on the basis of the design features and the mounting method room criticality level the purpose of the access restriction regime and other factors the presence of security providers video surveillance etc 2 During mounting the lock and the locking plate it is necessary to ensure their coaxial alignment within the catch free movement allowance 3 NO lock may be mounted outdoors on condi...

Page 8: ...ition If this is impossible remove the locking plate from the door Fasten the locking plate to the door providing the required clearances NC lock does not close when supply voltage is applied NO lock does not open when supply voltage is applied Check the presence of required clearances between the catch and the locking plate see section 6 9 MAINTENANCE The lock Promix SM213 is lubricated by the ma...

Page 9: ... low DC supply voltage the products correspond to class III as per ГОСТ 12 2 007 0 75 and are electrically safe Fire safety of the locks is ensured by use of non combustible or hardly combustible materials and low supply voltage 12 DISPOSAL The product is not hazardous for human life and health or for the environment disposal after its service life is performed without taking any special measures ...

Page 10: ...ing the manufacturing date and QCD mark on the body was manufactured and accepted in compliance with Specifications ПШБА 304268 002 ТУ obligatory requirements of state standards and current technical documentation recognized as fit for operation and packed by ETC PROMIX LLC PROMIX Engineering and Technical Center LLC Russia 214030 Smolensk Krasninskoye sh 35 lit A Phone 4812 619 330 www promix cen...