Promix-SM306
5
and the opening for the lock power wire.
4.
Drill holes Ø2mm (Ø5mm for the power wire) and fix the plate with self-tapping screws
6
.
5. Pull the latch out of the lock.Mount the lock
1
on the adjustment plate
3
using screws
4.
6. Remove the angular template
10
from the latch
2,
apply the latch to the door according to
the marks made earlier, and mark the latch fastening places.
7.
Drill two holes Ø7mm to a depth of at least 30mm.
8. Mark on the door end holes for barrel nuts
7
at the same level with the holes
Ø7mm
(see
Fig.2
).
9.
Drill two holes Ø10.2mm to a depth of at least 30mm at marked places.
10. Mount the latch
2
on the door using screws
5
and barrel nuts
7
(
see Fig.2).
11. Close the holes with barrel nuts
7
with plugs
9
.
12. Test operability of the installed lock together with the latch.
The latch
2
can also be fastened to the door by means of self-tapping screws
8
; to do this, drill
for them two holes Ø4-5mm to a depth of at least 30mm (instead of items 6.1.7-6.1.11).
A row of adjustment holes on the adjustment plate
3
serves for correcting the latch roller
position relative to the lock channel in the vertical direction (e.g., in case of the door sagging) and
in the horizontal direction.
6.2
CONNECTING PROCEDURE
The lock operation is controlled by means of energizing and de-energizing. For this purpose, a
controller (control board) or a switch (button) is generally used. The controller is mounted in
accordance with its certificate.
Connect the lock power wires adhering to the following polarity:
Red (black with a red stripe)
– positive pole of the power supply;
Black
– negative pole of the power supply;
Application of voltage of reverse polarity does not provide the lock operability but does cause
its failure.
2
7
5
Fig. 2
2 holes
2 holes