See operating voltage range in 5.2. Avoid supply of overvoltage.

 

Provide  a  reliable  electric contact. To  prevent  short-circuit, insulate  places  of 
connection.

 

 

Example of the lock connection to the remote control system Promix-RDS. 

 

7.

 

SPECIAL ASPECTS OF INSTALLATION AND 
OPERATION

 

1)  The possibility of using of the locks for restriction of access to the premises and the place of 

installation  (outdoors  or  indoors)  are  determined  by  the 

installation  organization

  on  the 

basis  of  the  design  features  and  the  mounting  method,  room  criticality  level,  the  purpose  of 
the  access  restriction  regime  and  other  factors  (the  presence  of  security  providers,  video 
surveillance, etc.).  

2)  To prevent deformations of the door due to attempts to open the door with the lock closed, it is 

recommended to mount the lock in the area of the door handle. 

3)  It is recommended to install the lock together with a door closer 

– this reduces impact load on 

the lock and extends its service life. 

4)  Operation of an installed NC lock should be tested only if the supply voltage can be applied 

thereto. 

8.

 

TROUBLE-SHOOTING

 

Troubles and problems 

Remedies 

The  lock  does  not  fix  the  latch  roller  (the 
door is not fixed in the closed state). 

Check  polarity  and  conformity  of  the  lock  supply 
voltage to the required value. 

Adjust  the  latch  (see  6.1)  so  that,  with  the  door 
closed,  the  roller  enters  the  snap  slot  before 
operation of the catch hook. 

The door is not closed completely since the 
latch does not enter the snap. 

Perhaps the catch hook was manually transferred 
to the “closed” position (see Fig. in section 4). 

Deblock  the  catch  hook  and  transfer  it  to  the 
“open” position manually. 

Lock 

 

Controller Promix-CR.RX 

 

Remote control 

Promix-CR.TX 

 

~220 V 

 

Summary of Contents for Promix-SM306

Page 1: ...ollowing information 1 Lock model 2 Patent number 3 Nominal supply voltage 4 Nominal consumed current 5 Date of manufacture and QCD mark 6 Identification number 7 Manufacturer s website For the list of lock modifications that can be ordered see 5 2 The color of the product is shown on the sticker stuck to the box after the product name Series colors Silver White Brown Other colors are provided opt...

Page 2: ...nauthorized opening of the lock is provided in the lock design optional Adjustment holes on the adjustment plate serve for correcting the latch roller position relative to the snap channel in the vertical direction e g in case of the door sagging and in the horizontal direction As the door is closed the latch enters the slot in the lock and overcoming the catch hook force is fixed transferring the...

Page 3: ...3 1 as per GOST 15150 69 with extended temperature range ambient temperature from 30 to 50 С Relative air humidity not higher than 98 at 25 С or lower temperatures without moisture condensation and hoar frost formation installation indoors or outdoors excluding ingress of moisture dust dirt etc inside the lock 5 2 TECHNICAL DATA Modification Promix SM306 00 Promix SM306 10 Version normally opened ...

Page 4: ...earances are ensured between the latch and the lock the clearances being provided by the angulartemplate10 see Fig 1 b The latch roller is at the center of the lock slot to provide this the base edges of the latch and the lock must be at the same level see Fig в in section 3 2 Mark positions of the latch and the lock 3 Apply the adjustment plate 3 to earlier made marks and mark optimum places for ...

Page 5: ...ck together with the latch The latch 2 can also be fastened to the door by means of self tapping screws 8 to do this drill for them two holes Ø4 5mm to a depth of at least 30mm instead of items 6 1 7 6 1 11 A row of adjustment holes on the adjustment plate 3 serves for correcting the latch roller position relative to the lock channel in the vertical direction e g in case of the door sagging and in...

Page 6: ... the lock closed it is recommended to mount the lock in the area of the door handle 3 It is recommended to install the lock together with a door closer this reduces impact load on the lock and extends its service life 4 Operation of an installed NC lock should be tested only if the supply voltage can be applied thereto 8 TROUBLE SHOOTING Troubles and problems Remedies The lock does not fix the lat...

Page 7: ...d in the manufacturer s packing in rooms with an ambient temperature of 30 to 50 С and a relative humidity not higher than 98 at 25º С in compliance with storage conditions as per GOST 15150 69 Locks transportation conditions must comply with group C as per GOST 23216 78 in terms of exposure to mechanical factors and Ж2 as per GOST 15150 69 in terms of exposure to climatic factors 11 SAFETY REQUIR...

Page 8: ...h the operation requirements Mechanical damages or disassembly of the products by the Buyer Non observance of the transportation and storage rules On expiration of the warranty service period the manufacturer provides after warranty service on a contractual basis 14 ACCEPTANCE AND PACKING CERTIFICATE Electromechanical lock Promix SM306 in quantity of ____ pieces 1 pc by default bearing the manufac...