See operating voltage range in 5.2. Avoid supply of overvoltage.
Provide a reliable electric contact. To prevent short-circuit, insulate places of
connection.
Example of the lock connection to the remote control system Promix-RDS.
7.
SPECIAL ASPECTS OF INSTALLATION AND
OPERATION
1) The possibility of using of the locks for restriction of access to the premises and the place of
installation (outdoors or indoors) are determined by the
installation organization
on the
basis of the design features and the mounting method, room criticality level, the purpose of
the access restriction regime and other factors (the presence of security providers, video
surveillance, etc.).
2) To prevent deformations of the door due to attempts to open the door with the lock closed, it is
recommended to mount the lock in the area of the door handle.
3) It is recommended to install the lock together with a door closer
– this reduces impact load on
the lock and extends its service life.
4) Operation of an installed NC lock should be tested only if the supply voltage can be applied
thereto.
8.
TROUBLE-SHOOTING
Troubles and problems
Remedies
The lock does not fix the latch roller (the
door is not fixed in the closed state).
Check polarity and conformity of the lock supply
voltage to the required value.
Adjust the latch (see 6.1) so that, with the door
closed, the roller enters the snap slot before
operation of the catch hook.
The door is not closed completely since the
latch does not enter the snap.
Perhaps the catch hook was manually transferred
to the “closed” position (see Fig. in section 4).
Deblock the catch hook and transfer it to the
“open” position manually.
Lock
Controller Promix-CR.RX
Remote control
Promix-CR.TX