EMERGENCY OPENING OF THE LOCK 

For  emergency opening of the  lock,  insert  a  wire (e.g., a  paper  clip) and,  having  caught the 

part “lever” (see the Figure below), move it until the lock operates. 

 

6.3 

CONNECTING PROCEDURE 

The lock operation is controlled by means of energizing and de-energizing. For this purpose, a 

controller  (control  board)  or  a  switch  (button)  is  generally  used.  The  controller  is  mounted  in 
accordance with its certificate. 

 
Purpose of terminals: 
1-2 Lock energizing. 
3 Normally open contact of the sensor. 
4 Common contact of the sensor. 
5 Normally closed contact of the sensor.  
 
Connect  the  lock  power  wires  adhering  to  the 

following polarity: 

Terminal 1 

– positive pole of the power supply; 

Terminal 2 

– negative pole of the power supply; 

Application  of  voltage  of  reverse  polarity  does  not 

provide the lock operability but does cause its failure.  

 

 

Move the lever until 

operation 

Lever 

Summary of Contents for Promix-SM308.10.1

Page 1: ...the following information 1 Lock model 2 Patent number 3 Nominal supply voltage 4 Nominal consumed current 5 Date of manufacture and QCD mark 6 Identification number 7 Manufacturer s website For the list of lock modifications that can be ordered see 5 2 The color of the product is shown on the sticker stuck to the box after the product name Series colors Silver White Brown Black Other colors are p...

Page 2: ...dle on the door The spring loaded pusher of the lock is connected to the door position sensor The operating principle of the sensor is described in 6 3 5 TECHNICAL DATA 5 1 OPERATING CONDITIONS The lock operation environment must be explosion safe free of current conducting dust or gases that cause metal corrosion and destroying insulation of current conductors and electric elements free of curren...

Page 3: ... than s 1 10 Minimum pause between pulses s 15 20 Built in sensors door position sensor Maximum switch current of the sensor DC А 0 2 Maximum switch voltage of the sensor DC V 24 Sensor output signal type dry contact Lock weight not more than kg 0 27 Holding force not less than kg 250 Initial latch pushing out force not less than kg 1 2 Manufactured against order Lock and latch overall and mountin...

Page 4: ...m the locker wall edge 3 Connect the lock to the power supply see 6 3 4 Insert the latch into the lock 5 Test operability of the lock as voltage is applied the lock must push out the latch 6 Fasten the latch to the door at a distance of 20 3mm from the base edge of the lock see Fig below 7 Test operability in door closing Fastening self tapping screws 15 Locker wall edge Base edge of the lock 3 ho...

Page 5: ...r a switch button is generally used The controller is mounted in accordance with its certificate Purpose of terminals 1 2 Lock energizing 3 Normally open contact of the sensor 4 Common contact of the sensor 5 Normally closed contact of the sensor Connect the lock power wires adhering to the following polarity Terminal 1 positive pole of the power supply Terminal 2 negative pole of the power supply...

Page 6: ... criticality level the purpose of the access restriction regime and other factors the presence of security providers video surveillance etc 2 To prevent deformations of the door due to attempts to open the door with the lock closed it is recommended to mount the lock in the area of the door handle 3 It is recommended to install the lock together with a door closer this reduces impact load on the l...

Page 7: ... in mounting and maintenance Due to low DC supply voltage the products correspond to class III as per ГОСТ 12 2 007 0 75 and are electrically safe Fire safety of the locks is ensured by use of non combustible or hardly combustible materials and low supply voltage 12 DISPOSAL The product is not hazardous for human life and health or for the environment disposal after its service life is performed w...

Page 8: ...ctual basis 14 ACCEPTANCE AND PACKING CERTIFICATE Electromechanical lock Promix SM308 in quantity of ____ pieces 1 pc by default bearing the manufacturing date and QCD mark on the body was manufactured and accepted in compliance with Specifications ПШБА 304268 003 ТУ obligatory requirements of state standards and current technical documentation recognized as fit for operation and packed by ETC PRO...

Reviews: