background image

Promix-RDS.01

 

 

6

 

9.

 

MAINTENANCE

 

The controller: special maintenance is not required. 
The remote control: if the LED does not light up or glows dimly it is necessary to replace the 

battery of the remote control. To replace the battery, unscrew the screw on the back of the remote 
control and disassemble the body. 

10.

 

REQUIREMENTS OF SAFETY AND 

ENVIRONMENTAL ENGINEERING

 

Promix-RDS set meets the safety requirements as per GOST R IEC 60065-2009. 
Installation and operation of the controller Promix-CR.RX.03 must meet the safety 

requirements as per GOST 12.2.003-91. 

The controller Promix-CR.RX.02 meets the fire safety requirements as per GOST 12.1.004-91. 
Promix-RDS.01 set is not hazardous for life and health of people and for environment. After the 

expiration of the service life, the set can be disposed of without any special environmental 
protection measures. 

10.1 ELECTRICAL SAFETY REQUIREMENTS 

Due to low supply voltage the remote control Promix-CR.TX.01 is electrically safe.  
Electrical safety requirements for the controllers Promix-CR.RX.02 meet the requirements of 

protection against electric shock according to class II as per GOST R IEC 60065-2009. 

The insulation strength between the current-carrying circuits of the mains supply and the 

secondary circuits with a low-voltage complete device must withstand an AC voltage of 3750V of 
practically sinusoidal form with a frequency of 50±1 Hz. The electrical insulation resistance 
between the current-carrying circuits of the mains supply and the secondary circuits, depending on 
the climatic operating conditions, must be at least of the following values:  

- with a low-voltage complete device - 10 MOhm; 
- at the highest value of temperature - 4 MOhm;  
- at the highest value of relative humidit

y (98% at 25°С) 

- 1 MOhm. 

The residual voltage between the pole contacts of the power cord must not exceed 31V one 

second after disconnecting from the power grid. 

In the controller Promix-CR.RX.02 there are no circuits that lead to leakage currents. 

11.

 

STORAGE AND TRANSPORTATION

 

Prior to putting into operation, the products must be stored in the manufacturer’s packing, in 

rooms with ambient air temperature of -30 to +50 

°С and relative humidity not higher than 98% at 

25 °С according to the storage condit

ions as per GOST 15150-69. 

The products transportation conditions must comply with group C under GOST 23216-78 in 

terms of exposure to mechanical factors, and Ж2 under GOST 15150

-69 in terms of exposure to 

climatic factors. 
 

 

Summary of Contents for RDS.01

Page 1: ...eiver and controller unit are designed as a single unit controller Promix CR RX 03 hereinafter the controller The receiver of the controller receives control signals of remote controls Promix CR TX 01 The power supply unit of the controller is used to control the connected actuators 2 DELIVERY SET Controller Promix CR RX 03 1 pc Remote control Promix CR TX 01 with a battery 2 pcs Operating manual ...

Page 2: ...erforms the following functions programming of remote controls and control time of the actuator applying or removing supply voltage to from the actuator for a specified time on the signals of the programmed remote controls disconnecting the actuator from the power supply unit protection when the current consumption by the actuator exceeds the preset level audible signaling of the controller curren...

Page 3: ...ontrol Promix CR TX 01 it sends a unique code via a radio channel The controller Promix CR RX 03 receives the sent code and if this code is recorded in the controller memory see Section 7 activates its output contact for the programmed time the supply voltage is applied to or removed from the actuator what is accompanied by a continuous beep signal If the current in the circuit of the actuator exc...

Page 4: ...open state when there is no supply voltage and in the closed state when the supply voltage is applied A normally closed actuator is in the closed state when there is no supply voltage and in the open state when supply voltage is applied Position 3 programming of the controller 7 PROGRAMMING THE CONTROLLER The supplied remote controls are already recorded in the controller memory The factory settin...

Page 5: ...roller emits double short beeps during which the programming is carried out 7 Pressing the button of the programmed remote control increases the open lock time by 1 second The set time in seconds corresponds to the number of beeps 8 If no action is performed during 5 seconds the controller switches from the programming mode into the operating mode confirming it with three beeps 9 Determine the typ...

Page 6: ...s per GOST R IEC 60065 2009 The insulation strength between the current carrying circuits of the mains supply and the secondary circuits with a low voltage complete device must withstand an AC voltage of 3750V of practically sinusoidal form with a frequency of 50 1 Hz The electrical insulation resistance between the current carrying circuits of the mains supply and the secondary circuits depending...

Page 7: ...omponents and units free of charge Costs of delivery to and from the place of repair shall be borne by the Buyer Warranty liabilities do not cover any defects and damages caused by Improper maintenance by the Buyer Use of the products under conditions that do not comply with the operation requirements Mechanical damages or disassembly of the products by the Buyer Non observance of the transportati...

Reviews: