TECHNICAL SPECIFICATIONS 

 

Design 

Operating position 

DC voltage supply, V 

Current consumption, 

А

 

basic 

(serial) 

 (horizontally) 

 (vertically) 

10÷14 

0.65  

(12V) 

-01* 

 (horizontally) 

 (vertically, armature plate up) 

11÷14 

0.28  

(12V) 

-02* 

 (horizontally) 

 (vertically, armature plate down) 

11÷14 

0.28  

(12V) 

-03* 

 (horizontally) 

 (vertically, armature plate up) 

22÷26 

0.24  

(24V) 

-04* 

 (horizontally) 

 (vertically, armature plate down) 

22÷26 

0.24  

(24V) 

Design 

Ambient air temperature

 T

amb.

, °

С

 

Voltage supply pulse 

duration T

pd

, sec 

A pause between voltage 

supply pulses, sec 

basic 

(serial) 

from -40 to +35 

0.5÷60 

6xT

pd

  (at least) 

from +35 to +50 

10xT

pd

  (at least)

 

-01* 

from -40 to +35 

not regulated 

from +35 to +50 

0.5÷120

 

0.5

х

T

pd

  (at least)

 

-02* 

from -40 to +35 

not regulated 

from +35 to +50 

0.5÷120 

0.5

х

T

pd

  (at least)

 

-03* 

from -40 to +30 

not regulated 

from +30 to +50 

0.5÷120

 

0.5

х

T

pd

  (at least)

 

-04* 

from -40 to +30 

not regulated 

from +30 to +50 

0.5÷120

 

0.5

х

T

pd

  (at least)

 

*on request 
 

5.

 

DESIGN AND OPERATING PRINCIPLE 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for SHERIFF-9.1

Page 1: ... access control systems audio and video door phones code access panels regular push button or switch 2 OPERATING CONDITIONS Climatic operating conditions ambient air temperature see Para 4 relative air humidity not more than 95 at 35 С and with lower temperatures without condensation and frost formation installing indoors and outdoors in the place protected from the direct moisture ingress dust an...

Page 2: ...y armature plate down 22 26 0 24 24V Design Ambient air temperature Tamb С Voltage supply pulse duration Tpd sec A pause between voltage supply pulses sec basic serial from 40 to 35 0 5 60 6xTpd at least from 35 to 50 10xTpd at least 01 from 40 to 35 not regulated from 35 to 50 0 5 120 0 5хTpd at least 02 from 40 to 35 not regulated from 35 to 50 0 5 120 0 5хTpd at least 03 from 40 to 30 not regul...

Page 3: ...hod of installation the level of premise accountability assignment of access restriction and other factors security CCTV etc The lock operates when applying and interrupting the voltage supply and for it is usually used a controller control board or a switch button Controller installation is done according to the technical data sheet Attention operating voltage supply range of the lock see Para 4 ...

Page 4: ...es resulting from improper maintenance by the Buyer using the lock in conditions that do not conform to the operating requirements mechanical damages or disassembly of the lock by the Buyer violation of transportation and storage regulations PACKING AND ACCEPTANCE CERTIFICATE Electromagnetic lock Sheriff 9 1 with the specified date of manufacture is made and accepted in accordance with TU 3428 003...

Reviews: