3.5. Adapting for cutting
To
adapt
the
carriage
for
oxy-fuel
or plasma cutting, remove the welding torch holder,
and install a rod for cutting and a cutting torch holder (Fig. 8).
For oxy-fuel
cutting,
use the 3 mm hex wrench to unscrew three screws fixing the
cable
anchor,
and
use
the
same
screws
in
the
same position to secure the bracket of
the gas manifold. Then,
use the 4 mm hex wrench to attach
a
gas
manifold
to
the
bracket
with the M5x45 screw.
Fig. 8.
Installing a cutting torch holder, gas manifold, and arc ignition cable
For plasma-cutting, use the arc ignition cable to connect the carriage to the
cutting circuits as shown in Fig. 7.
Plasma cutting
Oxy-fuel cutting
Oxy-fuel/plasma
cutting
Gas manifold
(optional)
oxy-fuel cutting
Cutting torch holder (optional)
Rod for cutting