CHAPTER 5
Pronar T683P
5.21
DANGER
Before removing the filter, reduce the pressure in the supply line. When removing the filter
slide, hold the cover with the other hand. Point the filter cover away from you.
5.3.4 AIR TANK DRAINAGE
FIGURE 5.10. Air tank drainage
(1) drain valve, (2) air tank,
The scope of service activities
Swing out the drain valve pin (1) located in the lower part of the tank (2) - the
tank is located on the brackets of the right longitudinal member of the lower
frame.
The compressed air in the tank will remove water outside.
After releasing the stem, the valve should close automatically and stop the
outflow of air from the tank.
In the event that the valve stem does not want to return to its position,
the entire drainage valve must be unscrewed and cleaned, or replaced
with a new one (if it is damaged) - see chapter 5.3.5.