24
Buttons and LED - Technical Specs
By pressing button (5) again, the scanning angle changes from 10° to
45° and 90°. Press once again on (5) to switch to point mode.
6) In order to switch the instrument off, press the power button (1) for
more than three seconds.
The horizontal and vertical lines can be combined at your wishes.
Explanation of LEDs
Green flashing MODE LED: The instrument is currently leveling.
Green MODE-LED: The instrument is level.
Red flashing ALARM LED: Out of self-leveling range
Red ALARM LED: Usage of manual mode
Technical Specifications
Leveling accuracy
± 2,3 mm/30 m
Vertical accuracy
± 2,3 mm/30 m
Orthogonal accuracy
± 30 seconds
Self-leveling range
± 4°
Working range
250-400 m with the universal
detector PNLUD14
Laser class
2, output below 1 mW
Laser diode
635 nm (red), 520 nm (green)
Horizontal lines
1
Vertical lines
0-2 (according to model)
Power Supply
Rechargeable Li-Ion battery or
C batteries
Operating time
ca. 35 h, depending on active
laser lines
Before starting to use the instrument, please verify the accuracy of the
instrument as described in the next chapter „ Accuracy Check“.