background image

 

 

2.3

 

Disassembly 

To disassemble the turn plate, proceed as in sub-section .1.1 Mounting the turn plate on the 
90/130P trolley, but in the reverse order. 

3

 

Use 

3.1

 

Operating instructions 

The turn plate functions are controlled from the motor control box. The 
motor control box functions vary depending of the end effectors used 
together with the turn plate. The joystick controls the variable rotation 
speed of the turn plate. The turn plate has endless rotation angle. 

4

 

Safety 

The maximum load must not be exceeded (max-load, se heading 6 
Technical specifications). The trolley and the end effectors may not be used for lifting people. The 
operator is asked to be aware of the risk of injury that exists when raising or lowering the end 
effector. Avoid putting your arm through the handlebar when trying to get hold of or pick up 
something from the end effector. The operator must always be aware of not holding his hands or 
other parts of his body under a hanging load. 

Always lower the end effector to the lowest possible level that the circumstances at ground level 
allow for, before any transport of goods is attempted. The load shall always be centered and stand 
as close to the column as possible in order to provide maximum stability. Be especially careful 
when passing over thresholds, door steps, cables and other 

4.1

 

Storage and transport 

When transporting and storing the turn plate attached to a lift-trolley, the power cable between 
the lifters power pack and the motor control box must be unplugged. 

The trolley is only intended for in-door use and on flat plain ground.  

5

 

Maintenance 

To ensure that your Turn device will function at its best it is important to give it regular 
maintenance as specified below  

Summary of Contents for 19470

Page 1: ...Complete Turn Device Model 19470 Also for 19471 19474 19475 19480 User s manual Original instructions ...

Page 2: ...achment is used Questions Contact your supplier or the manufacturer Pronomic AB Visiting address Bäckvägen 18 192 54 Sollentuna Sweden Postal address Box 5504 192 05 Sollentuna Sweden www pronomic se Tel 46 8 544 706 60 E mail sales pronomic se support pronomic se R210831 ...

Page 3: ...bly 3 3 Use 3 3 1 Operating instructions 3 4 Safety 3 4 1 Storage and transport 3 5 Maintenance 3 5 1 Every day 4 5 2 Every month or as needed 4 5 3 Sign and decals 4 5 4 Troubleshooting 4 6 Technical data 6 6 1 Max torque 7 6 2 Time for 90 degree turn 7 7 Approved attachments for Lift Drive trolleys 8 8 Drawings 9 8 1 Overview 9 8 2 Dimensions 10 EC DECLARATION OF CONFORMITY FOR PARTIAL MACHINERY...

Page 4: ...rate manual delivered with the lift trolley After many years of service your trolley and turn plate should be discarded in an environmentally correct way 1 1 Warranty The warranty applies for one 1 year from the date of delivery for material and manufacturing errors For the warranty to apply maintenance should be carried out according to instructions This warranty does not cover normal maintenance...

Page 5: ... the trolley and that the cable carrier is not too short or too long 2 2 Mounting the turn plate on the 175 225P trolley 1 Undo the screws in the slide that are provided to hold the loading platform The screws that come with the trolley cannot be used since they are too long Lift the turn plate into place against the slide and position the accompanying spacer key between the turn plate and the sli...

Page 6: ...your arm through the handlebar when trying to get hold of or pick up something from the end effector The operator must always be aware of not holding his hands or other parts of his body under a hanging load Always lower the end effector to the lowest possible level that the circumstances at ground level allow for before any transport of goods is attempted The load shall always be centered and sta...

Page 7: ...tight 3 Labels check that the labels are secure and fully legible They are there for your safety 5 3 Sign and decals Check that the following signs and decals are attached and are fully legible Sign decal Description Placement Unit designation Decal with serial number One decal on the control box and one decal on the attachment Instruction decal Decal instructing the operator Front of the control ...

Page 8: ...e power pack to the motor control box are intact 2 The turn plate does not turn but the motor works A See above under heading Symptom section 1 B Check through the listed tasks in section 2 5 maintenance 3 The turn plate moves slowly A See above under heading Symptom section 1 4 The turn plate sounds strange while turning A Check through the listed tasks in section 2 5 Maintenance ...

Page 9: ...lete turn devices 19470 19480 Turn 19400 19401 1940 Outer dimensions LxWxH 34x1 16x361 Rotation angle Dimension from floor to rotation center point Lift Drive 90P 130P 305 mm Lift Drive 175 225P 300 mm Turning speed w o load see diagram Max torque see diagram Max load 220 kg depending of the maximum capacity of the lift trolley Weight of unit 21 5 kg Intermittence 15 per 10 min maximum load Voltag...

Page 10: ...7 6 1 Max torque 6 2 Time for 90 degree turn Table on turning speed ...

Page 11: ...8 X X X 16338 X 16041 16044 X X 16048 16049 X X 17182 X X 17231 X X X X X X 17241 X X X X X X 17710 X X X X X X 17720 X X X X X X 17730 X X X X 17740 X X X X 17940 X X X 17972 X X 17980 X X 19511 X X 19201 X X 19285 X X 19470 X X 19471 X X 19472 X X 19473 X X 19474 X X 19475 X X 19476 X X 19477 X X 19478 X X 19479 X X 19480 X X 20205A 10 X X X X 20080 X X X X X X 21851 21854 X X X X 220066 220069 ...

Page 12: ...9 8 Drawings 8 1 Overview ...

Page 13: ...10 8 2 Dimensions ...

Page 14: ...plied directives 2006 42 EC Machinery directive 2014 30 EU EMC directive Applied standards SS EN ISO 12100 2010 Safety of machinery General principles for design Risk assessment and risk reduction SS EN ISO 13854 2019 Safety of machinery Minimum gaps to avoid crushing of parts of the human body We hereby declare that the above referenced machine built and equipped with attachments included in this...

Page 15: ...12 Serial number Signature Inspector Place date Pronomic AB SWEDEN Box 5504 192 05 Sollentuna Turn Unit 19470 19474 19480 19471 19475 ...

Page 16: ...Distributed by ...

Reviews: