background image

1/4 

INQL3-MAR09 
03/03/09 WW 

QL3 PRESSURE CONTROL VALVE 

INSTALLATION & MAINTENANCE INSTRUCTIONS

 

SPECIFICATIONS 

ELECTRICAL

 

SUPPLY VOLTAGE....................….15-24 VDC 
SUPPLY CURRENT...................….250mA max. 
COMMAND SIGNAL 

 

 

VOLTAGE..................…..0-10 VDC  

 

CURRENT..............…….4-20mA differential 

COMMAND SIGNAL IMPEDANCE 
 

VOLTAGE..................…..4.7 K

 

 

CURRENT..................….100 

 

ANALOG MONITOR SIGNAL   
 

VOLTAGE...............…….0-10 VDC @ 10mA max 

 

CURRENT……………….4-20mA Sinking or Sourcing 

MECHANICAL

 

PRESSURE RANGES¹...............0 to 5 psig through 0-150 psig 
OUTPUT PRESSURE¹................0-100% of range 
FLOW RATE 
FORWARD & EXHAUST .............25 SCFM max @ 120 psig inlet & 
 

 

 

     100 psig outlet 

 

 

 

     (708L/min @ 8.27 BAR inlet & 6.89 

 

 

 

     Bar outlet)  

MIN. CLOSED END VOLUME.…..5 in³ 
FILTRATION RECOMMENDED…40 micron actual 
LINEARITY………………...........…<±0.3% F.S. BFSL ²  
HYSTERESIS……………………….0.05% F.S. 
ACCURACY ..............................……<±0.4% F.S.  ²  
RESOLUTION………………………0.05% F.S. 
WETTED PARTS‡ .................Elastomers - Buna N (3) 
 

 

 

Manifold - Aluminum Nickel Plated 

 

 

 

Valves - 430FR SS, 360 Brass 

 

 

 

           Seal material:  Viton & Buna-N 

 

 

 

P.Transducer - Utem 1000, Aluminum, 

PHYSICAL 

OPERATING TEMPERATURE....32-158ºF [0-70ºC] 
DIMENSIONS…………………….2in.X2 in.X4.4 IN    
 

 

 

    (51mmX51mmX111mm) 

WEIGHT.................................…....1.06 lb [0.50 Kg] 
PROTECTION RATING...........…NEMA 4 / IP65 
HOUSING...............................……Aluminum (Anodized) 
VOLUME BOOSTER.....................Electroless Nickel Plate 

¹  Pressure ranges are customer specified.  Custom pressure ranges are avail-
able.  Any range 5 to 150. 
² Dependent on response adjustments.  Valve can be field adjusted for best 
response for the actual application 
³ Other elastomers are available.  Consult factory. 

DESCRIPTION

 

   
 

The QL3 is a closed loop electronic pressure regulator consist-

ing of two solenoid valves, an internal pressure transducer, and an 
electronic  control  circuit  integrally  mounted  to  a  unique  volume 
booster. The output pressure is proportional to an electrical input 
(command  signal).  The  pressure  is  controlled  by  activating  the 
solenoid valves, which apply pressure to the pilot side of the vol-
ume  booster.  One  valve  functions  as  inlet  control,  the  other  as 
exhaust.  The  output pressure of the volume booster is measured 
by  a  pressure  transducer,  which  is  internally  mounted  and  pro-
vides a feedback signal to the electronic control circuit. This feed-
back  signal  is  compared  against  the  command  signal  input.  Any 
differences  between  the  command  signal  and  the  pressure  feed-
back signal causes one of the solenoid valves to open to adjust the 
pressure in the pilot of the volume booster.  Pilot pressure is ad-
justed so that desired output pressure is achieved and maintained. 
Since  it  is  the  actual  desired  work  pressure  that  is  being  sensed 
and  fed  back  to  the  control  circuit,  any  mechanical  hysteresis  of 
the  air  piloted  volume  booster  is  automatically  compensated  for. 
This allows for our extraordinary accuracy and repeatability.   
   
  The  QL3  improves  and  builds  on  the  proven  Proportion-Air 
QB3  series  high  performance  by  using  a  current  driven  variable 
orifice solenoid valve and a unique analog PID circuit.  This vari-
able orifice solenoid avoids the pressure “steps” prevalent in most 
feed and bleed I/P’s.  The PID circuit integrates error out quickly 
resulting  in  superior  resolution.    The  combination  of  a  stepless 
solenoid valve with a high speed analog PID on a high flow vol-
ume  booster  allows  lots  of  air  to  be  moved  in  a  hurry,  but  pre-
cisely. 
   
  Command inputs come in a choice of either a 0-10 Vdc or 4-20 
mA.  The  QL3  also  provides  an  electrical  monitor  signal  for  out-
put  to  a  panel  meter  or  controller  for  data  acquisition  or  quality 
assurance needs. The monitor signal comes from the internal pres-
sure transducer.  All QL3’s come standard with a 0-10 volt moni-
tor  signal  with  4-20  mA  optional.    Providing  this  monitor  signal 
as part of our standard package eliminates the need to purchase a 
separate transducer. 
 

 

 

The uniqueness of the volume booster design is that it has no 

stamped  gaskets  or  special  molded  diaphragm  or  seal  parts.    All 
of  the  parts  related  to  normal  maintenance  are  standard  o-rings.  
Complete repair kits are available, but in case emergency repair is 
needed parts should be available from any fluid power distributor 
or  even  most  neighborhood  hardware  stores.  Since  all  sealing 
parts are o-rings a large variety of chemical compounds are read-
ily  available.    You  can  select  the  compounds,  which  are  most 
ideally suited to your process and environment. 
 

 

 

The  QL3  is  used  for  pressures  up  to  150  psig.  For  pressure 

ranges  between  150  and  500  psig,  see  the  Proportion-Air  QB3H 
series. 

Before you get started, please read these warnings: 

♦ 

Examine the product.  Ensure that you received what 
you ordered. 

♦ 

Read this guide first before you start and save it for 
later use. 

♦ 

You must have a good understanding of what the ad-
justments are on this product before using them. 

♦ 

All compressed air and power should be shut off before 
installing, removing or performing maintenance on this 
product. 

♦ 

Installation and use of this product should be under the 
supervision and control of properly qualified personnel 
in order to avoid the risk of injury or death. 

Courtesy 

of 

CMA/Flodyne/Hydradyne 

 Motion 

Control 

 Hydraulic 

 Pneumatic 

 Electrical 

 Mechanical 

 (800) 

426-5480 

 www.cmafh.com

Summary of Contents for QL3 Series

Page 1: ...sure that is being sensed and fed back to the control circuit any mechanical hysteresis of the air piloted volume booster is automatically compensated for This allows for our extraordinary accuracy and repeatability The QL3 improves and builds on the proven Proportion Air QB3 series high performance by using a current driven variable orifice solenoid valve and a unique analog PID circuit This vari...

Page 2: ...age of this sheet 3 Proceed to the appropriate section corresponding to the type of valve being installed NOTE ALL COLOR CODES RELATE TO QL3 S ORDERED FROM THE FACTORY WITH PRE ASSEMBLED QBT C X CABLES Voltage Command Valves TFEE All voltage command QB3 s use a single ended command mean ing the DC Common serves as both the power and command common Current Command Valves TFIE All current command QL...

Page 3: ... levels Verify the accuracy of your measuring equipment before re calibrating Consult factory if you have any questions or require assistance For valves ordered with MAX calibrated pressure Max inlet pressure 5 through 10 psi positive 15 psig 1 bar 10 1 up to 30 psig 0 70 up to 2 bar 35 psig 2 4 bar 31 up to 100 psig 2 1 up to 7 bar 110 psig 7 6 bar 101 up to 150 psig 7 up to 10 3 bar 165 psig 11 ...

Page 4: ...H REGARD TO CONSEQUENTIAL DAMAGES WARRANTIES OF MERCHANTABILITY DESCRIPTION AND FITNESS FOR A PARTICULAR PURPOSE WARNING Installation and use of this product should be under the supervision and control of properly qualified personnel in order to avoid the risk of injury or death ORDERING INFORMATION QL 3 T F E E xxx A Ø 8 SERIES SIZE 3 1 4 NPT Ports CONTAINER COMMAND INPUT MONITOR SIGNAL MAXIMUM C...

Reviews: