background image

Some people may feel skin irritation or experi-

ence a very sensitive feeling in the skin due to 

electrical stimulation. If this occurs, stop using 

these devices and consult your Physician.

If skin under the pad feels irritated after using the 

stimulator for a long period of time, use the 

stimulator for a shorter period of time.

Minor redness at stimulation placement is a 

normal skin reaction. It is not considered a skin 

irritation, and it will normally disappear within 30 

minutes after the electrodes are removed. If the 

redness does not disappear after 30 minutes from 

the removal of electrodes, do not use the 

stimulator again until after the excessive redness 

has disappeared.

Turn off your device if the stimulation feels 

unpleasant or does not provide pain relief.

Keep this device out of the reach of children.

Use this device only with the pads and 

accessories recommended by the manufacturer.

Do not use this device when driving, operating 

machinery or when swimming.

Before removing the Mini Patch, be sure to turn it 

OFF, avoiding unpleasant stimulation.

If your pain does not improve, (!) or if it continues 

for four to six days, stop using this device and 

consult your Physician.

8

Summary of Contents for Direct CM7257

Page 1: ...OPERATION MANUAL direct Electronic patch for pain treatment Read Before Using...

Page 2: ...ntroduction to prorelax direct 10 1 Components and Functional Parts of the Unit 2 Prior to Use 3 Installing Changing the Battery 4 Use and Functions 5 After Use Cleaning and Maintenance 14 Device Elec...

Page 3: ...ied with this product which should help you reduce your pain In order to achieve all the benefits from the direct we ask you to carefully read the following safety information and warnings Intended Us...

Page 4: ...ations Do not use this Device if any of the following conditions are present Do not use this device if you have a cardiac pacemaker implanted defibrillators or any other implanted metallic or electron...

Page 5: ...hest because the introduction of electrical current into the chest may cause rhythm disturbances to the heart Do not place the prorelax direct on or around your head The effects of stimulation of the...

Page 6: ...of prorelax direct Read this User Manual before using this device for the first time Keep this manual available whenever you use this device This device is intended for individual person use only Thi...

Page 7: ...your physician prior to using this device following recent surgical procedures Stimulation may disrupt the healing process Use Caution and consult your Physician before using the Mini Patchif any of t...

Page 8: ...electrodes are removed If the redness does not disappear after 30 minutes from the removal of electrodes do not use the stimulator again until after the excessive redness has disappeared Turn off you...

Page 9: ...ch suppresses the sensationof pain that would otherwise serve as a protective mechanism Adverse Reactions Skin irritation and burns under the pads have been reported by some people who have applied el...

Page 10: ...ing muscles in the upper and lower extremities arm and or leg due to strain from exercise or normal household and work activities 1 Components and Functional Parts of the Unit 10 OFF Intensity DOWN Sw...

Page 11: ...lectrode with the contact plugs up onto a flat surface Place the device with the contact jacks down onto the Electrode pad so that plugs and jacks are aligned Then press down until completely snapped...

Page 12: ...By pressing On button again the device starts to work at the lowest level of intensity The device has 10 levels of intensity for strength of treatment Select these intensity levels by simply pressing...

Page 13: ...by taking the electrode pad at the edge and pulling carefully Don not grasp at the unit Replace the electrode pad onto the clear plastic shield 5 3 Never remove the unit when it is switched on 5 4 No...

Page 14: ...e again until it is completed dry Remove the battery from the device if it is not going to be used for some time Do not expose the device to direct sunlight and protect it against dirt and moisture Wi...

Page 15: ...ishes The electrode is good for 20 30 times of use 20 min each time Be sure to use only prorelax originally supplied of Self Adhesive Electrodes 510k Nr K082065 Contact prorelax for ordering informati...

Page 16: ...Placement of Electrode 16...

Page 17: ...Electrode pad dirty Device not applied properly Battery dead Electrode pad dirty or short circuited Battery dead Electrode pad worn out or dirty Device not applied properly Replace battery Insert Bat...

Page 18: ...torage Condition Weight Dim prorelax direct WL 2301B Single Channel 0 30V 20 at 500 Ohm load Adjustable from 0 60mA 20 150 250uS 30 60Hz 1 Lithium Coin Cell battery CR2032 20 minutes 50 F 10 to 104 40...

Page 19: ...r relating thereto Battery electrodes and other accessories are warranted to be free from defects in workman ship and materials at the time of delivery The distributors reserve the right to replace or...

Page 20: ......

Reviews: