•   Ensure that no metallic objects (e.g. belt buckles or necklaces) come 

into contact with the electrodes during stimulation. If you are wearing 

jewellery or have piercings in the area to be treated (e.g. a navel piercing),  

these must be removed before using the device. Failure to do so could 

result in spot burns.

•  Keep the device away from children.

•   Make sure not to confuse the electrode cables including contacts with 

your headphones or other devices and do not connect the electrodes to 

other devices. 

•   Do not use the device whilst using other devices that transmit electrical 

impulses into your body.

•   Do not use in the vicinity of highly flammable substances, gases or ex-

plosives.

•  Do not use rechargeable batteries and always use the same battery types.

•   During the initial few minutes, use the device while sitting or lying down 

to minimise the risk of injuries as a consequence of isolated cases of vagal 

responses (feeling of faintness). If you feel faint, immediately switch off 

the device, lie down and support the legs in an elevated position (approx. 

5 -10  min).

•   Treatment of the skin with moisturising lotions or ointments beforehand 

is not recommended as this considerably increases the electrode wear 

and may cause unpleasant current peaks.

•   This device is not intended for use by people with restricted physical, sen-

sory (e.g. reduced sensitivity to pain) or mental skills or a lack of experien-

ce and/or lack of knowledge, unless they are supervised by a person who 

is responsible for their safety or are instructed by such a person in how to 

use the device.

•   If the adhesive capability of the adhesive electrodes decreases, please 

replace them immediately. Only use the device again with new adhesive 

electrodes. Otherwise the unequal adhesion of the adhesive electrodes 

may lead to skin injuries. Replace the electrodes with new ones after  

having used them 20 times at the latest.

Damage

•   If the device is damaged, do not use it and contact your retailer or the 

specified Customer Services address.

•   In order to perform the effectiveness of function by the device, do not 

drop the device or disassemble the device.

•   Check the device for signs of wear and tear or damage. If there are such 

signs of wear and tear or damage or if the device was used improperly, it 

must be returned to the manufacturer or retailer before further use.

•  Switch the device off immediately if it is faulty or not working properly.

•   Do not attempt to open and/or repair the device yourself. Repairs may 

only be carried out by Customer Services or authorised retailers. Failure 

to comply will result in voiding of the warranty. 

•   The manufacturer is not liable for damage resulting from improper or  

careless use.

Notes on handling batteries 

•   If your skin or eyes come into contact with battery fluid, rinse the affected 

areas with water and seek medical assistance.

•   Choking hazard! Small children may swallow and choke on batteries. 

Store the batteries out of the reach of small children.

•  Observe the plus (+) and minus (-) polarity signs.

•   If a battery has leaked, put on protective gloves and clean the battery 

compartment with a dry cloth.

•  Protect batteries from excessive heat.

•  Risk of explosion! Never throw batteries into a fire.

•  Do not charge or short-circuit batteries.

•   If the device is not to be used for a relatively long period, take the batte-

ries out of the battery compartment.

Summary of Contents for SUPER DOU plus

Page 1: ...OPERATING INSTRUCTION SUPER DUO TENS EMS plus 1639...

Page 2: ...e carefully and keep them for lateruse besuretomakethemaccessibletootherusersand observe the information they contain Signs and symbols WARNING Warning instruction indicating a risk of injury or damag...

Page 3: ...e electrical impulses that are sent into the tissue influence the transmission of stimulation into nerves nerve centres and muscle groups in the application area Electrostimulation usually only has an...

Page 4: ...ormance e g after a marathon Thanks to integrated massage technology TENS EMS SuperDuoPlus units are also able to relieve muscle tension and combat fatigue with a program based on the sensation and ef...

Page 5: ...rs If you are receiving medical treatment In the event of complaints linked to stimulation treatment If you suffer from persistently irritated skin due to long term stimulation at the same electrode s...

Page 6: ...dhesive capability of the adhesive electrodes decreases please replace them immediately Only use the device again with new adhesive electrodes Otherwise the unequal adhesion of the adhesive electrodes...

Page 7: ...s to the stimulator use the following steps to prepare your skin at the electrode placement sites 1 Determine the placement sites for the electrodes 2 Wash the area with mild soap and water do not use...

Page 8: ...Always ensure the limb is secured to prevent movement 2 Do not turn the unit on until all electrodes and lead wires are properly attached Placement of the Electrode Pads forTENS Treatment of Pain Note...

Page 9: ...gra dually You may use any of the modes for EMS SHOULDERS Place one half of the pad on the front of your shoulder and the otheron the side BACK OF THIGHS Place each pair of pads horizontally across y...

Page 10: ...ation Program Pulse width uS Pulse rate Hz Waveform Type P1 P2 P3 P4 P5 P6 P7 P8 P9 260 260 260 260 156 260 156 260 260 156 50 260 uS 15 60 60 2 60 60 7 60 60 Constant Burst Constant Dense Disperese M...

Page 11: ...time you turn the device on Note If you change programs during the course of a therapy session the treatment time will not reset unless you manually reset it by performing the steps described above S...

Page 12: ...s 5 10 15 20 25 30 35 40 45 50 55 and 60 min utes Time will countdown on the display in 1 minute increments for the duration of your session The device turns off automatically when the therapy time ha...

Page 13: ...d electrodes Do not pull on the cables but on the connectors attached to the ends of the cables Store the stimulator with the cables in a clean dry place Electrode The electrode pads are disposable an...

Page 14: ...completely flat batteries should be disposed of through specially designated collection boxes recycling points or electronics retailers You are legally required to dispose of the batteries For environ...

Page 15: ...re he can send the device free of cost and what documentation is required Filing a warranty claim can only come into consideration if the buyer can submit a copy of the invoice proof of purchase and t...

Page 16: ...Well Life Healthcare Ltd 6F No 168 Lide St Jhonghe District New Taipei City 23512 Taiwan EXCLUSIVELY IMPORTED AND DISTRIBUTED IN EUROPE BY EUROMEDICS GmbH Hauptstra e 169 D 59846 Sundern Germany info...

Reviews: