background image

GE1600 User Manual 

 

 

 

 

 

70-0016A-C

 

Prosilica Inc. 

 

 

24 

Trigger Timing Diagram 

 

User Trigger 

Logic Trigger 

Exposure 

Readout 

Trigger Ready 

Imaging 

Tpd 

Trigger  
Latency 

Interline Time 

Expose Start  

Delay 

Trigger  
Jitter 

Idle 

Registered  
Exposure Time 

Readout Time 

N

 

 

N+1

 

 

N

 

 

N+1

 

 

Summary of Contents for GE1600

Page 1: ...Prosilica Inc www prosilica com tel 604 875 8855 fax 604 875 8856 2007 Prosilica Inc All rights reserved prosilica USER MANUAL February 21 2007 GE1600 GE1600C...

Page 2: ...Specifications 2 Supported Features 3 Mechanical 4 Connections 5 Cleaning the Sensor 10 Adjusting the C mount 11 Camera Installation 12 System Optimization 17 Trouble Shooting 19 Addendum 20 GE IO Sc...

Page 3: ...ge during shipping VERIFY ALL EXTERNAL CONNECTIONS Verify all external connections in terms of voltage levels power requirements voltage polarity and signal integrity prior to powering this device CLE...

Page 4: ...Temperature 0 to 50 Celsius Operating Humidity 20 to 80 non condensing Size 39mm height x 51mm width x 80mm length Weight 170g Hardware Interface Standard IEEE 802 3 1000BASE T 100BASE TX Software In...

Page 5: ...dge falling edge any edge level high level low Exposure Time 10 microseconds to 60 seconds in 1 microsecond increments Gain 0 to 21dB Region of Interest ROI independent x and y control with 1 pixel re...

Page 6: ...70 0016A C Prosilica Inc 4 Mechanical 79 5 50 20 26 26 M3 3MM DEEP 6 PLCS TYP 51 3 39 1 All dimensions are in mm Add 0 3mm for color cameras due to addition of IR blocking filter Figure 1 GE SERIES me...

Page 7: ...GE1600 User Manual 70 0016A C Prosilica Inc 5 Connections 1 5 6 2 3 4 7 Figure 2 GE SERIES connection diagram...

Page 8: ...General Purpose I O Pin out Camera rear view 12 Isolated Ground The General Purpose I O port uses a Hirose HR10A 10R 12SB connector on the camera side The mating cable connector is Hirose HR10A 10P 1...

Page 9: ...the Ethernet port to a peripheral device connected to the camera ISOLATED GROUND These signals are internally connected to isolated ground At least one of these signals must be connected to the users...

Page 10: ...Trigger Ready Indicates when the camera will accept a trigger signal Trigger Input A relay of the trigger input signal used to daisy chain the trigger signal for multiple cameras Readout Valid when ca...

Page 11: ...ca or from http www digikey com This port can accept from 5V to 17V DC with the inner conductor being positive power and the external conductor being ground However the suggested nominal voltage is 12...

Page 12: ...er carefully using a small flat head screw driver Clean both sides of the IR filter using the same techniques as explained below for the sensor window DO NOT TOUCH ANY OPTICS WITH FINGERS OIL FROM FIN...

Page 13: ...h the camera When the locking ring is loose unthread the ring a few turns from the camera face A wrench suitable for this procedure can be provided by Prosilica P N 11 0048A Image to Infinity Use a c...

Page 14: ...bytes however typical Jumbo Frames are around 9000 bytes Frame size is the number of bytes per packet and the larger the frame size the less the computer CPU will be loaded due to the processing of in...

Page 15: ...that came with the network card o Once the driver is installed open the Network Connections Dialog as follows From the Windows desktop select start then select Control Panel then double click on the N...

Page 16: ...an IP address of 169 254 x y where x and y can be any number Press the TAB key after entering the IP address and the subnet mask will automatically be entered The subnet mask is 255 255 0 0 Click OK t...

Page 17: ...Cable lengths must not exceed 100 meters Power Connection The camera requires a 12V DC power supply that can source a minimum of 500 mA of current See the Connections section of this document for mor...

Page 18: ...e recognized If the camera does not appear in the Viewer list after approximately 10 seconds then try disconnecting and reconnecting the power If it still does not appear restart the viewer If it stil...

Page 19: ...l Panel then double click on the Network Connections icon Double click the relevant network card listed or right click the relevant network card and select Properties This will open the properties win...

Page 20: ...000 If the list contains a property called Receive Descriptors then change this value to its maximum value Select OK to save properties o From the main properties dialog as in Figure 9 make sure that...

Page 21: ...that lens iris is fully open Check exposure time in room lighting an exposure time of 30ms should be adequate to see an image If image is still black contact Prosilica o Is the image white If the came...

Page 22: ...GE1600 User Manual 70 0016A C Prosilica Inc 20 Addendum...

Page 23: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 VDD1 GND1 IN1 IN2 OUT3 OUT4 NC GND1 GND2 NC IN4 IN3 OUT2 OUT1 GND2 VDD2 ISO TXD ISO 5V GALVANIC ISOLATION BOUNDARY ISOLATED 5V POWER RS 232 TXD SYNC OUT 3 LOGIC SY...

Page 24: ...V TTL RECEIVER USERS TRIGGER CIRCUIT CABLE SIDE SYNC OUT 3 1 2 3 4 5 6 7 8 9 10 11 12 HIROSE HR10A 10P 12P 1 2 3 4 5 6 7 8 9 10 11 12 The trigger circuit is connected to a Texas Instruments SN74ACT244...

Page 25: ...R 5V TTL DRIVER SYNC OUT 1 5V TTL RECEIVER The trigger circuit is connected to a Texas Instruments SN74ACT244PWR buffer driver inside the camera The required trigger input current is less than 10uA an...

Page 26: ...Prosilica Inc 24 Trigger Timing Diagram User Trigger Logic Trigger Exposure Readout Trigger Ready Imaging Tpd Trigger Latency Interline Time Expose Start Delay Trigger Jitter Idle Registered Exposure...

Page 27: ...tes when the next Exposure cycle can begin such that the Exposure will end after the current Readout o Interline Time is the time between sensor row readout cycles o Imaging is high when the camera im...

Page 28: ...triggering cycle time whereby the camera image sensor is exposing and reading out simultaneously then the User Trigger signal should be applied as soon as a valid Trigger Ready is detected o In this...