background image

 

12

connections but do not indicate the location of the 
cross. RJ-11 cables used for telephone 
connections are often crossed. Even new cables 
are often crossed. This seldom affects the 
performance of standard analog telephone lines 
(POTS). Digital telephone lines and old 
touch-tone phones may be polarity sensitive, so a 
crossed cable may prevent then from working 
properly.  
 

CABLE REPAIR   

1. General 

Information: 

The following section 

provides information to the user about 
common cable types, common failures and 
repairs. It is not meant to be an exhaustive 
study of the topic, just some basic 
information that the uninitiated may find 
helpful.  

2.  Cable damage: 

When a cable tests   

badly, either the wire of the connectors or 

both may be at fault. If the cable has been 
installed and working, then it’s likely that the 
wire or connectors have been abused in 
some way. The wire portion of the cable can 
be damaged by being crushed (under the left 
of a desk), stretched (pulled sharply around a 
corner), punctured (by a nail or staple), over 
loaded (hit by lighting), etc. Similar abuses 
will damage the Connectors on the ends of 
the cable. The connectors can also be 
damaged by excessive insertion and removal 

Summary of Contents for 15-AT002

Page 1: ...CABLE SNIFFER REMOTE MT 7057 User s Manual 1 st Edition 2012 2012 Copy Right by Prokit s Industries Co Ltd ...

Page 2: ...1 Contents 1 Introduction 2 2 Safety rules and warning 2 3 Product features 5 4 Specifications 5 5 Front panel 6 6 Operation 8 7 Cable repair 12 8 Maintenance 17 9 Accessories 17 ...

Page 3: ...red telephone cables SAFETY RULES WARNINGS 1 Read all instruction in this manual before using this tester Failure to do so may result in damage to the tester or injury to the user 2 Do not use this tester with its case open or with parts removed Doing so may damage the tester and or injure the user 3 When using this tester in schools and workshops responsible teachers or skilled personnel must con...

Page 4: ...hnicians who know the dangers of and the safety rules applicable to this type of equipment Failure to observe this precaution may result in damage to the tester or injury to the user 7 Do not touch the ends of the cables when making tests An Unexpected dangerous potential may be present Failure to observe this precaution may result in damage to the tester or injury to the user 8 Do not apply volta...

Page 5: ...ent to a warm environment Condensation of water inside and outside of the tester may produce dangerous conditions Allow the tester to warm to room temperature before using 16 Do not modify this tester Changing the design may make the tester unsafe and may result in injury to the user 17 Do not use this tester if it has undergone long term storage user unfavorable conditions 18 Do not use the teste...

Page 6: ...sed for longer than month Chemical leakage from the battery could damage the tester PRODUCT FEATURES 1 Test 4 types of cables 2 Simple one button test 3 Ergonomic portable handheld design 4 Tests installed wiring or patch cables 5 Remote unit stores in main unit 6 600ft test distance RJ 45 RJ 11 BNC 7 Convenient battery access 8 Built in battery test 9 LEDs indicate connections and faults 10 Beepe...

Page 7: ...es with Type A flat plug on one end and type B square Plug on other end BNC cables with male connectors 2 Faults Indicated No Connection Short Open crosses 3 Low Battery Indicator LED lights to indicate low battery 4 Case Dimensions 6 3x3 4x1 0 inches LxWxH 5 Weight 170grams 0 375Ibs without battery 6 Battery 1 standard 9 volt alkaline battery FRONT PANEL 4 in 1 DIAGRAM 6 ...

Page 8: ...7 ...

Page 9: ...MAIN and REMOTE unit The 4 in 1 Cable Tester consists of a Main unit and a Remote unit The Remote unit stores conveniently on the bottom of the Main unit It can be removed or replaced by sliding it from left to right or right to left respectively Use care when removing or replacing the Remote Some of the plastic edges are a little sharp The Remote is often attached to the Main unit when storing wh...

Page 10: ...e and the Main unit attached to the other to the other end of the cable These ends are often in different rooms and on different floors of a building 5 Performing the Test Once the Remote and Main unit are attached to the ends of the subject cable as described in 6 3 and 6 4 testing may begin simply press and release the test button on the Main unit observe the LED indicators and note the beeping ...

Page 11: ...ED Corresponding to the type of cable being tested must light Examine the table below the Numbered LEDs noting what LEDs should light If all of These LEDs do not light the cable has an OPEN fault If all of the appropriate Numbered LEDs light the cable is OK Note When testing an RJ 45 UTP cable the S LED must not light The 4 in 1 is intended to test complete cables It may not find faults in cables ...

Page 12: ...ed LED 3 Beepers Short LED Numbered LEDs If the connected LED light the Beeper emits 3 beeps and the Short LED lights the cable has a fault The Numbered LEDs indicate the location of a short Note In the Short mode the Numbered LEDs only indicate the location of the shorts The other connections in the cable are not indicated If more than 3 numbered LEDs light there may be multiple shorts in the cab...

Page 13: ...on failures and repairs It is not meant to be an exhaustive study of the topic just some basic information that the uninitiated may find helpful 2 Cable damage When a cable tests badly either the wire of the connectors or both may be at fault If the cable has been installed and working then it s likely that the wire or connectors have been abused in some way The wire portion of the cable can be da...

Page 14: ...Cables with Molded on ends Many cables have molded on ends that cannot be opened up for repair The entire cable must be replaced or the molded on end removed and replaced with a user serviceable connector These types of cables usually fail from Opens or Shorts They seldom fail from a Crossed connection 5 Cables with Crimped on RJ connectors Crimped on RJ connectors cannot be reused or repaired New...

Page 15: ...flict with the performance of the cable i e the cable tests badly but works OK or vice versa The following items list some of the reasons why 6 1 The 4 in 1 indicates the cable is not working but my LAN works OK Installed LAN cables with RJ 45 connectors that have been in service and working OK may test as Open Shorted or Crossed Here s why The EIA TIA 568 standard for LAN cable only uses 4 of the...

Page 16: ...2 wires each Not only must the 8 wires connect from end to end of the cable the pairs in the cable must connect to specific pins of RJ 45 plugs on to the ends of cable ignoring the pairing as described in EIA TIA 568 and the cable will test ok But when the cable is tried on the LAN it does not work This is because the lack of the proper pairing causes excessive cross talk in the cable preventing t...

Page 17: ...use 2 wires in a modular cable the modular cable which terminates in RJ 11 connectors could have as may as 6 wires in it The unused wires may have faults which the 5 in 1 identifies but these faults may have no effect on the working 2 wrie telephone circuit Many telephone cables with RJ 11 plugs jacks are wired inverse The 4 in 1 will show that a cable like this is crossed A cable like this revers...

Page 18: ...red To clean the outside of the tester use a cloth dampened with a mild detergent solution Do not use any abrasive cleansers or chemical solvents that may damage the case of the tester ACCESSORIES The 4 in 1 cable tester includes the following items Main unit Remote Female BNC Terminator Instruction Manual Carrying Case The group of products may be discontinued models specifications price or desig...

Page 19: ...4合一網路測試器 MT 7057 18 ...

Page 20: ...池 不含 二 安全注意事項 注意 此測試器不能用於測試帶有電壓之活線 若將活線 接於此測試器 可能會造成測試器損壞 使用前請細詳閱讀使用說明書 錯誤使用可能造成測 試器損壞 使用時請勿將機殼打開使用或自行更換內部零件 如 此可能造成測試器損壞 三 產品特色 1 可測試 4 種線材 2 單鍵操作 簡單方便 3 黑色噴膠外殼 握感舒適 4 具有自動掃描檢測網絡線 檢視跳接正確性 短 路 斷路及芯線排列順序等功能 5 具有電源狀態指示 6 明亮清楚的 LED 燈顯示 四 產品規格 1 測試線材 UTP STP RJ 11 USB BNC 2 尺寸 6 3x3 4x1 0 inches LxWxH 3 重量 170 克 不含電池 4 適用電源 9V 電池 不含 ...

Page 21: ... 1 S 燈號 表示屏蔽線 接地線 2 1 8 燈號 表示對應的線路 3 SHORT 燈灯號 表示線材有短路 4 CONNECTED 燈號 表示受測試的線材連接是 正確的 5 CROSSORER 燈號 表示受測試的線材連接有 交錯的問題 6 NO CONNECTION 燈號 表示没有相通的線 或是接頭没有插好 有可能是接觸不良 7 BATTERY GOOD 燈號 表示本測試器的電源 正常 可正常使用 8 BATTERY LOW 燈號 表示本測試器的電源不 足 應及時更換電池 以免對測試結果產生影響 20 ...

Page 22: ...21 ...

Page 23: ... S 燈也應該同時 亮 表示這條線正確 如果 SHORT 燈亮 表示有短路 同時短路的路線 與所對應的小紅燈也同時亮 如果 CONNECTED 燈亮 而小紅燈有幾顆不亮 表示對應的路線有断路 如果 CROSSOVER 燈亮 就表示有交錯或順序相 反 2 測試電話線 如果 6 芯電話線則小紅燈亮 1 6 4 芯電話線亮 2 5 2 芯電話線 3 4 同時 CONNECTED 燈 也亮 3 測試 USB 線材 CONNECTED 燈和 S 4 小紅燈同時亮 表示線 材正確 反之和測試雙絞線的原理一樣 4 測試 BNC 同軸電纜 CONNECTED 燈和 1 2 小紅燈同時亮 表示 線材正確 ...

Page 24: ... 2012 Prokit s Industries Co LTD All rights reserved 2012001 C 23 ...