Remarks:
1. Please make sure a 9-volt alkaline battery has been installed in
the battery compartment.
2. Remember to always keep the GND switch off, if you are not
testing the shielding.
Caution:
Don't connect cable tester to the live circuits as it may be
damaged by over voltage.
Test for 10-Base-T, AT&T 258A, EIA/TIA 568 and Token Ring
Cable
1. Plug one end to the marked
▲
jack of the master unit and the
other end to the remote terminator (you may plug both ends to the
master unit only, if you are not doing a remote test).
2. Push the power switch on, the power LED will flash to show the
power is working properly.
3. As soon as the power is switched on, the LEDs on the remote
terminator will start to scan one by one.
4. If the cable is OK, the LEDs corresponding to each pair
connected will light GREEN . If the LED is lighted GREEN first
and RED after (mix.) or it is unlighted, the cable is bad.
5. If the cable is shielded , you may test shielding by pushing the
GND switch on. The corresponding LEDs and GND LED will
light up with all green except the LED of pair 3&6 is kept off. If
any LEDs is lighted green first and red after or unlighted, it's
showing the shielding is bad.
3PK-NT008
ENHANCED NETWORK CABLE TESTER
10
Summary of Contents for 3PK-NT005
Page 17: ...3PK NT005 RJ 45 RJ 11 USOC 4 USOC 6 USOC 8 1 2 ON 3 4 5 6 9V 3PK NT005 16...
Page 22: ...NOTE 21...