Remarks:
Please make sure a 9-volt alkaline battery has been installed in the
battery compartment.
Caution:
Don't connect cable tester to the live circuits as it may be
damaged by over voltage.
Test for USOC 4/USOC 6/USOC 8 Modular Cable
1. Plug one end to the master tester and the other end to the remote
terminator (you may plug boths end to master unit only, if you are
not doing a remote test).
2. Push the power switch on, the power LED will flash to show the
power is working properly.
3. As soon as the tested cable is inserted the LEDs on the remote
terminator will start to scan one by one.
4. If the tested cable is OK, the corresponding pair of LEDs will
light up all Green.
5. If the corresponding pair of LEDs is lighted all RED, the cable
was wired reversely.
6. If the LEDs light up GREEN first and Red after (mix) or it is
unlighted, the cable is bad.
3PK-NT005
MULTI- MODULAR CABLE TESTER