5. Press
“
▲
”
or
“
▼
”
button as to set up the temperature.
6. Adjust the airflow knob to set up the required air volume.
7. Hold the handle, the equipment begins to heat. Adjust the knob of airflow in
order to set proper air volume, operate normally when temperature is stable.
8. Put the handle back on the holder after work, the SMD station switched from
heating mode to cooling - off mode automatically. When the temperature is
lower than 100
℃
, the station switching to standby mode.
9. Switch the power off and unplug the power cord if there has no operation for a
long time.
Attention
Please set up the temperature as lower as possible in high airflow volume as to
prolong heating element service life and better IC chips protection.
Setting up Temperature
1. Press
“
▲
”
or
“
▼
”
button to set up the temperature, the screen displays the
setting temperature.
2. Press “
▲
” once the temperature degree increase 1
℃
, and the screen displays
the setting temperature.
Press “
▼
” once the temperature degree decrease 1
℃
,and the screen
displays the setting temperature.
When press the
“
▲
”
or
“
▼
”
button continuously, the temperature will
increase or decrease rapidly, after the button is released, the screen
displays temperature for two seconds and displays setting temperature
or display
“- - -“
for standby mode.
5