3.2.8 Measuring temperature
To avoid any electric shock and/or damage to the meter, do not
attempt a frequency measurement if the voltage is over 250V for
DC current or AC current(valid value).
1. Turn the rotary switch to the
position
and press “FUNC/Hz” to choose
or
2. Insert the red plug of the thermocouple into the end of
, and insert the black
plug into COM socket.
3. Directly read the temperature value from the display screen after the reading is
stable.
Notes:
The maximum measuring temperature for the K-type thermocouple
dispatched at random is 250
/482
, and its instant measuring value can reach 300
/572
.
3.2.9 NCV test (non-contact voltage detection)
Turn the rotary switch to NCV position, and place the top of the meter approach
the conductor. If the meter detects the AC voltage, The beeper will sounds alarms
at different frequencies, and the indicator will be flashing.
Note
:
1. Voltage may still remain in the absence of any indication. The operator shall not
rely on non-contact voltage detector to check the presence of voltage. The
detection operation may be affected by various factors, including socket design,
insulation thickness and type.
2. When the voltage is input into the meter's input terminal, the voltage sensor
LED may be on as a result of induced voltage.
3. External sources of interference (like flashlight and motor) may trigger
non-contact voltage detection.
4. Technical parameters
4.1 Overall parameters
Operating environment:
600V CAT
Ⅱ
Pollution level: 2
Altitude < 2000 m
Working temperature & humidity: 0~40
O
C (The requirements will not be
considered when temperature is less than 10
℃
and relative humidity is
below 80%).
Storage temperature & humidity: -10~60
O
C (batteries shall be removed when RH
is below 70%).
Coefficient of temperature: 0.1
accuracy/
O
C (<18
O
C or >28
O
C).
Allowable max voltage between terminal to be measured and ground: 600V DC
Summary of Contents for MT-1236
Page 17: ...1 Pro sKit MT 1236 1 1 A B 60V DC 30V AC 3 1 5V AAA 600V...
Page 18: ...AC DC 600 V European Union 1 2 600V 250V mA F600mA 250V A F10A 250V 2 2 1 LED...
Page 26: ...5 2 F600mA 250V F10A 250V 3 x 1 5V AAA...
Page 27: ...MT 1236 3 5 6 1 Pro sKit MT 1236 1 1 A B 60Vdc 30Vac 3 1 5V AAA...
Page 28: ...600V AC DC CAT 600 V European Union 1 2 600V 250V mA F600mA 250V A F10A 250V...
Page 29: ...2 2 1 LED 2 2 NCV V mV V...
Page 37: ...5 2 F600mA 250V F10A 250V 3 x 1 5V AAA...
Page 38: ...MT 1236 12 0755 83692415 83692986 83246594 83247554 400 169 9629 0755 83692143...