12
Range
Accuracy
Resolution
600uA
±(1.5%+10d)
0
.1μA
6000uA
1μA
60mA
10μA
600mA
100μA
6A
±(2.0%+15d)
1mA
10A
10mA
Max input current : 10A (less than 15 seconds). Frequency
response: 40-100Hz
Overload protection:0.5A/250V fuse, 10A/250V fuse. Duty Circle
Indication: (0.1%-99.9%)
Resistance (Ω)
1. Turn the function/range selection knob to Ω, insert the red and
black test lead separately to VΩHz and COM input terminal.
2. Connect the test lead to the tested resistance in parallel, the
tested resistance value will be displayed on LCD
3. Auto Range
mode is preset when turning on, press “RANGE”
button to switch to Manual Range mode.