MT-2017
Protective Function
Analog Multimeter
User’s Manual
1
st
Edition
,
2011
©2011 Copyright by Prokit’s Industries Co., Ltd.
1
INTRODUCTION
This Multi-meter is an accurate, safe, battery operated, rear
tilt-stand, easy to operate handheld instrument with robust
protective holster alongside and the adjustable back tilt device
with hook-up design. It can offer accurate, reliable measurement
of DC/AC Voltage, +/-DCV, DC Current, Resistance and Diode,
LED, Transistor, Decibels, Continuity test and Capacitance with
very high sensitive quality movement, double-sided glass-epoxy
PCB & good-designed circuit, as well as mirrored Aluminum dial
plate etc. It has the perfect full overload & mis-used protection via
two Fuses, Oxide Varactor & Diodes. It is an ideal instrument for
indoor use in the laboratory, school, workshop, hobby and home
applications.
SPECIFICATION
Safety Category: IEC61010-1, CAT II 1000V, CAT III 500V and
Pollution Degree 2.
Common Environment: 23
C
5
C, less than 75% RH.
Temperature Ranges:
0
C to 40
C, 32
F to 104
F for operating condition.
-10
C to
50
C, 14
F to 122
F for storage condition.
Humidity Scope: Operating condition less than 90% RH.
Storage condition: less than 80% RH.
Size: 160(W)
x 105(D)
x 40(H) MM
Weight: 390g approx. (including batteries 3pcs)
Accessories: One set of Test Leads;
Two Spare Fuses: 0.5A/250V & 10A/250V,
Additional Option Accessory: MT2007-C special for capacitance
measurements 1 set
2
Test
Functions
Range
Accuracy
Remarks
DC V
0-0.1-2.5-10-50-2
50 V-1000V
3%
FSD.
4%
FSD.
For
1000V
Input Impendence:
20K
Ω
/V Overload
Protection: Max.
1000V AC/DC
BUT 0.1V/2.5V/10V
250V Max.
Null DCV
±-5V, ±25V
5%
FSD.
Input Impedance: 40K
Ω
/V
Overload 1000V Max.
AC V
0-10-50-250V
-1000V
4%
FSD.
5%
FSD.
For
1000V
Input Impendence:
9K
Ω
/V Overload
Protection: Max.
1000V AC/DC
But 10V/50V only
250V Max. Band
width: 40 ~10K Hz
DC mA
0-0.05-2.5-25-25
0 mA,
10A
3%
FSD.
4%
FSD.
For 10A
Drop Voltage: 250 mV
Overload protected by
Fuses 0.5A/250V &
10A
/
250V at 10A
range, and Oxide
Varactor.<250V AC/
DC(5s). Max.
test time
1min. for 10A.
Ω
X 1: 0.2 ~ 2K
Ω
Midscale at 20
Ω
X 10: 2 ~ 20K
Ω
Midscale at 200
Ω
X 100: 20~
200K
Ω
Midscale
at 2000
Ω
X1K:
200~ 2M
Ω
4% of
ARC of
Scale
Length
Overload protected by
the Oxide Varactor &
Fuse <250V AC/DC
(5s).
3
Midscale at 0K
Ω
X10K: 2K ~20M
Ω
Midscale at
200K
Ω
Capacitance
(uF)
0.025-0.25-25uF(
C2), 2000uF(C1)
3%
FSD.
Approx.
Value
Use the optional
Accessory Kit
(MT-2007-C)
Use the R
x 1K range
BATT Check
0 ~ 1.5V: GOOD
- ? – BAD
0 ~ 9V: GOOD
- ? – BAD
5% of
ARC of
Scale
Length
Load Current:
270mA for 1.5V
25mA for 9V
Overload protected by
Fuse & Oxide
Varactor .<250V
AC/DC(5s).
Transistor
Check
hFE: 0-1000 via
special hFE
socket
Approx.
Value
At
Ω
X 10 Range
LED, Diode
Check
via special hFE
socket
Approx.
Value
At
Ω
X 10 Range
Decibel
-22 dB ~ + 62 dB
(0dB=1mW at
600
Ω
)
Approx.
Value
At ACV ranges
Continuity
Check
Beeper sounding
under 200 Ohm
Overload protected by
Fuse & Oxide
Varactor .<250V
AC/DC(5s).
POWER
Source
Internal Battery:
R6P, AA, 1.5V
2pcs, 6F22,
NEDA1604, 9V
1pc