MVI56E-AFC / MVI69E-AFC ♦ Enhanced Liquid and Gas Flow Computer
Configuring Site Parameters
ControlLogix® and CompactLogix™
Setup and Configuration Guide
ProSoft Technology, Inc.
Page 31 of 151
Parameter
Description/Example
AFC slave
indicates whether this is a primary or virtual slave.
Swap Words
If checked, swaps the Modbus words transferred through this port.
This parameter is only accessible to those data points that hold 32-bit
quantities (long integers, floats, totalizers).
Disable pass-
thru
The Modbus Pass-thru feature allows you to configure a Modbus
Pass-Thru region in the Virtual Slave (Project > Site Configuration).
See the
AFC Reference Guide
for detailed information.
Maximum
simultaneous
connections
Set the maximum number of connections for this server. Eight (8)
total connections are available and can be configured as required.
For example, each server might represent a different network. Server
1 might have a single connection while server 2 may have 3, server 3
with 2, and server 4 with 2 for a total of 8.
Reserved
connections
A
reserved connection
is one whose resources are always available
for use by this server, whether or not such a connection is currently in
use, so that regardless of activity on other servers, this number of
connections to this server can always simultaneously exist. This
setting must not exceed the maximum number of connections
permitted for this server if that maximum is non-zero. The total
number of reserved connections over all servers must not exceed the
maximum number of connections permitted overall. Server #1 always
has at least one reserved connection. Range 1 to 8, default 1 with
corresponding for others as 0 to 8..
Idle connection
timeout, min.
Specify the number of minutes that a connection may be idle before
being disconnected. A timeout of 0 means no timeout (the connection
may remain idle indefinitely).