MVI56E-AFC / MVI69E-AFC ♦ Enhanced Liquid and Gas Flow Computer
Configuring Common Parameters
ControlLogix® and CompactLogix™
Setup and Configuration Guide
ProSoft Technology, Inc.
Page 71 of 151
Resetting upon Archive Period End or Reset upon Event
Use the EAFC Manager to configure the resettable accumulator to be reset when the
archive period ends or when an event occurs. Refer to
Event Log
in the
AFC Reference
Guide
for more information on configuring and monitoring events.
Resetting when the Accumulator Rollover Value is reached
The resettable accumulator is reset when the accumulator rollover value is reached. You
must configure the accumulator rollover value using the EAFC Manager (
Meter
Configuration
).
Resetting a resettable accumulator applies to that accumulator for both the meter and for
all its streams.
Archive Accumulators
The archive accumulators are part of the current archive (archive 0) data. These
accumulators are automatically reset when a new archive is generated. Refer to the
Modbus Dictionary
–
Meter Accumulator
section.