\Qn
Set or query the serial port flow control setting.
n=0
: No flow control is being used.
n=1
: RTS/CTS hardware flow control is being used.
n=4
: Transparent software flow control. Uses escaped XON and XOFF for
flow control. XON and XOFF characters in data stream are escaped with the
@ character (0x40). @ in data is sent as @@.
+FCLASS=n
This command sets the RLXIC-SGinto a particular fax-mode operation, which
causes the internal hardware to process information presented in the Dial
command in a manner suitable for that type of information. Cannot be configured
in AceManager.
n=0
: Fax/data call.
n=8
: Normal interconnect.
+WVCLASS?
queries the current setting.
+IPR=n
I/O Port Rate: Sets the data rate for the serial port (DTE-DCE). C3x11 or C3x11E
only. Default is 115200. Cannot be configured in AceManager.
+WVLASS=n
This command sets the RLXIC-SG into a particular voice-mode operation, which
causes the internal hardware to process information presented in the Dial
command in a manner suitable for that type of information. Cannot be configured
in AceManager.
n=0
: Normal interconnect (using line 1).
n=9
: Fax/data call.
$QCVAD=n
Mode for answering data or fax with the A (answer) or via auto answer (S0=1).
C3x10 or C3x10E only. Cannot be configured in AceManager.
*CTSE=n
Clear To Send Enable: This feature asserts CTS when there is a network
connection.
n=0
: Disabled (Default).
n=1
: Enable assertion of CTS when there is network coverage.
RS232 voltage levels:
Positive = Network coverage.
Negative = No coverage.