Adding Multiple Modules in the Rack (Optional)
Important: This procedure is for multiple MVI69L-MBSs running in the same CompactLogix rack
You can add additional modules of the same type to the rack.
1
Add a new MVI69L-MBS to the ProSoft Configuration Builder (PCB) project.
2
Export the module configuration as an L5X file.
3
Add a new MVI69L-MBS to the RSLogix 5000 project.
4
Import the .L5X file into RSLogix 5000 for the new module as an Add-On
Instruction.
2.6.1 Adding an Additional Module in PCB
1
Start ProSoft Configuration Builder.
2
Right click
D
EFAULT
L
OCATION
(which you can rename) and choose
A
DD
M
ODULE
.
3
Right-click
N
EW
M
ODULE
and choose
C
HOOSE
M
ODULE
T
YPE
.
4
In the
Choose Module Type
dialog box, select
MVI69L
in the
P
RODUCT
L
INE
F
ILTER
area, and then select
MVI69L-MBS
as the
M
ODULE
T
YPE
. Click
OK
.
5
Select the
MVI69L-MBS
in the tree and repeat the above steps to add a
second (or more) module in the PCB project.