MVI56-MNETCR ♦ ControlLogix Platform
Configuring the MVI56-MNETCR Module
Modbus TCP/IP Multi Client Communication Module for Remote Chassis
User Manual
ProSoft Technology, Inc.
Page 23 of 127
February 14, 2011
2.1.4 Creating the Module - Local Rack
1
In the
C
ONTROLLER
O
RGANIZATION
window, expand the I/O configuration
node.
2
Select the
1756
B
ACKPLANE
node, and then click the right mouse button to
open a shortcut menu. On the shortcut menu, choose
N
EW
M
ODULE
...
3
This action opens the
S
ELECT
M
ODULE
dialog box.
4
Select the
1756-M
ODULE
(G
ENERIC
1756
M
ODULE
)
from the list and click
OK.
5
Set the Module Properties values as follows:
Parameter
Value
Name
Enter a module identification string. The recommended value is
MNETCR.
Description
Enter a description for the module. Example: Modbus TCP/IP
Multi Client Communication Module for Remote Chassis.
Comm Format
Select
D
ATA
-INT
(Very Important)
Slot
Enter the slot number in the rack where the MVI56-MNETCR
module is to be installed.
Input Assembly Instance
1
Input Size
42
Output Assembly Instance
2
Output Size
42
Configuration Assembly Instance 4
Configuration Size
0