5.2
Specifying Reference Temperature and Pressure (Reference
Conditions)
Measurements of gas and liquids are calculated based on their characteristics at
a specific temperature and atmospheric pressure. Specify the reference
conditions in this area. The default values are 15°C/101.325 kPaa (SI) and
60°F/14.696psia (US), which are the standard API base conditions. If configured
reference conditions are different from API base, the API calculations are done
twice as necessary to correct from flowing conditions to API base and then de-
correct from API base to your selected reference.