P-12
Installation Guide
3
GREEN (–)
Unlock
output
Programmable 500 mA, 7/10sec., 4sec., double 1/4 sec. pulse or 1/10sec
negative output.
4
WHITE /
BROWN
(–)
Arm output
500 mA ground output when the
button is pressed. This output is activated
500 ms before the LOCK pulse and deactivated at the same time as the LOCK
pulse ends.
Note: The system will also give an ARM/REARM pulse on this wire when it shuts
down the vehicle after a remote start.
5
WHITE /
GREEN
(–)
Disarm
output
500 mA ground output when the button is pressed. This wire is for disarming
OEM Alarm systems.
Note: System will also give a DISARM pulse before remote start.
6
BLUE /
WHITE
(+)
Positive
Door input
This input should be used in vehicles that use a positive-switching Dome Light
circuit. Connect to a Dome Light wire t12 V with a Door open.
CAUTION! You can only use either the NEGATIVE DOOR INPUT or the
POSITIVE DOOR INPUT wire. It is essential that the Module be connected in
such a way as to allow each one of the Doors to be detected by the remote
starter.
7
WHITE /
ORANGE
(–)
Starter Kill
output
The unit is equipped with a selectable passive- or active-arming Starter Kill circuit
that will immobilize the vehicle when the system is armed. This wire will provide a
constant 500-mA negative output when the system is armed (locked by remote)
or if remote started. This wire should be connected to a Single Pole Double-
Throw Relay (This wire will connect to Pin 85, on the Relay, and Pin 86 will be
connected to the Ignition wire).
A second benefit of the Starter Kill is the Anti-Grind feature. When the vehicle
has been remote started the Anti-Grind prevents the starter motor from re-
engaging when the ignition key is inserted in the Ignition switch and accidentally
turned to the CRANK position (The Starter Kill output becomes active during
remote starts).
8
ORANGE
(–) Parking
Brake
input
This input is for manual transmission vehicle ONLY. It is used in the Ready
Mode sequence and must be connected. The Parking Brake input must be given
a ground signal (-) when the Parking Brakes are applied.
9
PURPLE
(–)
External
Trigger
input
Programmable negative input (page-28). The External Trigger wire can be used
to operate as a negative trigger with the Trunk pin-switch or the Key Sense wire
(by default). The External Trigger wire can also be used for remote-starting/
stopping the vehicle with an external device. When the vehicle is running,
triggering this input will also activate Idle Mode.
10
WHITE (–)
Ground
out when
running
This wire provides a constant 500 mA negative output while the vehicle is remote
started. The output becomes active 1.5sec before Ignition, and becomes inactive
when the Module shuts down. The output can be used to activate external relays,
bypass kits, etc.
CAUTION! If multiple relays or modules are connected to the Ground Out wire,
ensure that they are all diode isolated in order to avoid feedback and damaging
the vehicle.