PGA-710 Autoanalysis System – How To Measure Guide
27
Figure 46: Ground the Charge Plate Monitor and
Confirm the zero (0) reference setting
Figure 47: Offset Voltage Measurement Concept
1. Confirm the Charge Plate Monitor (CPM) is
zeroed and floating (Figure 46).
2. Position the CPM at the point that offset
voltage is to be measured. Typically this is
approximately 15 to 40 inches from the
outlet of the ionizer, depending on process
and work requirements.
Worksurface
Ionizer
12 - 40 Inches
Auditing Ionizer Offset Voltage (Balance)
Ground
Portable CPM
Ground & Zero CPM (1 Volt Increments Preferred)
Place in Air Path @12-40", or at Desired Working Point
Insure No Grounded Objects in Air Path
Measure Offset Voltage & Document
Adjust Offset Voltage As Necessary