37
MARK68AF1001 Rev 2
Step 3: Use 18 Gauge Stranded Wire to make the connections between the T-Max and The
Aquafrixio as shown in the picture below.
Note the Grey Cord with terminal block that connects to the EXT START is for the Quick Start
function. This is a benefit for your customer so that they do not have to hit start on the Tmax display
itself. This way they can bypass the delay time and start their session directly on the screen. We
recommend using this function for your customer but it is not required.
If you choose not to use the Quick Start function you only need to connect the 18 gage wire to the
black cord.
When making the connection to the black “pig tail” cord, you will need to open the small screws and
you will place the 18 gage stranded wire in the two outside ports and connect to the J3 Contact on
the back of the Tmax.
Always make sure that the wires are all securely fastened by tugging on them lightly.