6
Figure 9 Figure 10 Figure 11
7.3.1 Input Wheel Parameters with Automatic Gauge
Pull the gauge against the rim keeping it in position for 2 seconds. A and D
parameters are automatically input with a sound “beep”, and enter the state of B
parameters input. Pull the gauge against the rim ,the computer will automatically
input B value, As is shown in figure 12,
In this state, all parameters can be modified manually. Choose the parameter to be
modified and press the key below the screen. For example, to modify Gauge A
parameter, press , a red line appearing in the A value interface indicates that
Gauge A is selected. Press to modify the current value. The increasing
or decreasing range equals the step set by the setting state. ( eg. If the step is 0.5
inch, To press once will increase by 0.5 inch.) While inputting parameters,
press to convert the unit of parameters, like “mm” or “inch”
Input finished, Press to save and return.
7.4 Standard Dynamic Mode
This function is to test the amount of unbalance on the inside and outside of the rim
while a wheel is rotating. Placing counterweight on the tested position of both sides of
the rim according to the displayed unbalance value can eliminate unbalance.
After installing the tire and inputting the parameters, Close the guard or press
Figure 12
WB-514 Wheel Balancer user’s manual