8
F2 to enter mode selection interface shown in figure 17. and then press F2 to
choose static mode. See figure 18.
Close the guard or press to start the motor and make the wheel rotate (figure
19). While waiting, in case of emergency you can open the guard or press to
stop rotating.
When the wheel stops rotating, the right side of the screen displays the unbalance
value. Rotate the wheel with hands and stop rotating when the red triangle cursor
moves to the middle of the rule (figure 20). Place a counterweight of 20g on the 12
o’clock position. (Static mode has no division of inside and outside )
Static measurement finished.
7.6 ALU1--ALU5 Modes
ALU mode refers to five counterweight sticking modes reduced according to the
shapes and sizes of most rims. ( figure 21)
Figure 17
Figure 19
Figure 18
Figure 20
WB-514 Wheel Balancer user’s manual