15
Remove the tire from the balancer using a tire changer. Assemble the tire and the rim
again. Align the nozzle and the mark by rotating the tire on the rim by 180 degrees
Replace the tire on the balancer and rotate the gas nozzle to 12 o'clock again. Press
and then press START key to do OPT measurement as shown in figures 36&37.
After measurement, rotate the wheel as shown in figure 38.
Mark again on the
outside tire of the marked point with the chalk. Assemble the tire with the changer to
make the new mark coincide with the nozzle. Now the displayed value is the residual
value after optimization.(see figure 39)
OPT operation finished. Press to exit.
Figure 36
Figure 37
Figure 38
Figure 39
WB-514 Wheel Balancer user’s manual