Low Cost 

Digital Multimeter User Manual 

Thank you for purchasing this Low Cost Digital Multimeter. This multimeter is the perfect 

introduction to meters, and data capture of standard measurements including DC & AC voltage, DC 

current, resistance, transistor, and diode testing. Just move the rotary switch to the correct position, 

plug in your leads and you’re good to go! 

Please familiarise yourself with the functions of the multimeter before use. We recommend 

retaining this manual for ease of reference. 

 

Improper use of this meter can cause damage, shock, injury or death. 

 

Always remove the test leads before replacing the battery or fuses. 

 

Before using this meter, please inspect the condition of the test leads and the meter itself for any 

damage. If damage is present, please discontinue use. 

 

Do not measure voltage if the voltage on the terminals exceeds 1000V above earth ground. 

 

Do not exceed the maximum limits of the input values shown in the specification tables on pages 

6-7 of this manual. 

 

Remove the batteries from the meter if it will be unused for an extended period of time. 

 

Always turn the function switch to the off position when not in use. 

 

 

2

Low Cost

Digital Multimeter User Manual

Thank you for purchasing this Low Cost Digital Multimeter. This multimeter is 

the perfect introduction to meters, and data capture of standard measurements 

including DC and AC voltage, DC current, resistance, transistor, and diode testing. 

Just move the rotary switch to the correct position, plug in your leads and you’re 

good to go!

Please familiarise yourself with the functions of the multimeter before use. We 

recommend retaining this manual for ease of reference.

• Improper use of this meter can cause damage, shock, injury or death.

• Always remove the test leads before replacing the battery or fuses.

• Before using the meter, please inspect the condition of the test leads and the 

meter itself for any damage. If damage is present, please discontinue use.

• Do not measure voltage if the voltage on the terminals exceeds 1000V above 

earth ground. 

• Use great care if voltages are greater than 30VAC RMS. Anything above this is 

considered a shock hazard. 

• Always discharge capacitors and disconnect power before performing diode, 

resistance or continuity tests. 

• Do not exceed the maximum limits of the input values shown in the 

specification tables on pages 

12, 13, 14 & 15

 of this manual.

• Remove the batteries from the meter if it will be unused for an extended period 

of time. 

• Always turn the function switch to the off position when not in use.

17/9/19   9:41 am

1

Summary of Contents for QM1500

Page 1: ...HOBBYIST Low Cost Digital Multimeter QM1500...

Page 2: ...PAGE LEFT INTENTIONALLY BLANK...

Page 3: ...Digital Multimeter User Manual Thank you for purchasing this Low Cost Digital Multimeter This multimeter is the perfect introduction to meters and data capture of standard measurements including DC an...

Page 4: ...racy 0 500 DC Voltage Range 200mV 1000V AC Voltage Range 200V 750V DC Current Range 2000 A 10A Resistance 200 to 2000k Diode Test Yes Transistor hFE Test Yes LCD Screen hFE Socket Function Switch 10A...

Page 5: ...his area Input Jacks V mA Positive input terminal for voltage resistance diode temperature frequency and capacitance COM Negative input terminal for voltage resistance diode temperature frequency and...

Page 6: ...to the V jack b 10A DC insert the red test lead banana plug into the 10A jack 3 Set the function switch to the desired position 4 Remove power from the circuit under test then open up the circuit at t...

Page 7: ...ng shows OL the diode is good b If both readings show OL the device is open c If both readings are very small or zero the device or circuit is shorted TRANSISTOR MEASUREMENT 1 Set the function switch...

Page 8: ...TION ACCURACY 2000 A 1 A 2 0 of reading 10 digits 20mA 10 A 200mA 100 A 10A 10mA 2 5 of reading 10 digits Overload Protection 500mA 250V fuse 10A range unfused Measuring Voltage Drop 200mV RESISTANCE...

Page 9: ...nect the test leads from the meter 2 Remove the cover 3 Gently remove the old fuse and install the new fuse into the holder 4 Always use a fuse of the proper size and value 500mA 250V 5 Replace and se...

Page 10: ...suspected defect fault arises and return the product along with proof of purchase to the place of purchase or distributor for assessment Distributer contact details are available on the last page of...

Page 11: ...PAGE INTENTIONALLY LEFT BLANK...

Page 12: ...Distributed by Electus Distribution Pty Ltd 320 Victoria Rd Rydalmere NSW 2116 Australia Ph 1300 738 555 Int l 61 2 8832 3200 Fax 1300 738 500 www electusdistribution com au...