background image

FUNCTIONS 

Max. Display 

2000 Count 

Basic Accuracy 

0.500% 

DC Voltage Range 

200mV – 1000V 

AC Voltage Range 

200V – 750V 

DC Current Range 

2000

μ

A – 10A 

Resistance 

200

Ω

 to 2000k

Ω

 

Diode Test 

Yes 

Transistor hFE Test 

Yes 

LCD Screen 

hFE Socket 

Function 

Switch 

10A Input Jack 

V

Ω

mA Input Jack 

COM Input Jack 

FUNCTIONS

Function Switch

Select a measurement range by turning the 

switch to the preferred option.

LCD Screen

Readings and measurements taken by the 

multimeter will display in this area.

Input Jacks

V

Ω

mA:

Positive input terminal for voltage 

resistance, diode, temperature, frequency 

and capacitance.

COM:

Negative input terminal for voltage, 

resistance, diode, temperature, frequency 

and capacitance.

10A:

Input terminal for 10A current.

SYMBOL

Diode Test

Ω

Ohms

Hz

Hertz (Frequency)

V

Volts

A, mA, 

μ

A

Current Range

AC

Alternating Current/Voltage

DC

Direct Current/Voltage

2

Summary of Contents for QM1500

Page 1: ...HOBBYIST Low Cost Digital Multimeter QM1500...

Page 2: ...PAGE LEFT INTENTIONALLY BLANK...

Page 3: ...Digital Multimeter User Manual Thank you for purchasing this Low Cost Digital Multimeter This multimeter is the perfect introduction to meters and data capture of standard measurements including DC an...

Page 4: ...racy 0 500 DC Voltage Range 200mV 1000V AC Voltage Range 200V 750V DC Current Range 2000 A 10A Resistance 200 to 2000k Diode Test Yes Transistor hFE Test Yes LCD Screen hFE Socket Function Switch 10A...

Page 5: ...his area Input Jacks V mA Positive input terminal for voltage resistance diode temperature frequency and capacitance COM Negative input terminal for voltage resistance diode temperature frequency and...

Page 6: ...to the V jack b 10A DC insert the red test lead banana plug into the 10A jack 3 Set the function switch to the desired position 4 Remove power from the circuit under test then open up the circuit at t...

Page 7: ...ng shows OL the diode is good b If both readings show OL the device is open c If both readings are very small or zero the device or circuit is shorted TRANSISTOR MEASUREMENT 1 Set the function switch...

Page 8: ...TION ACCURACY 2000 A 1 A 2 0 of reading 10 digits 20mA 10 A 200mA 100 A 10A 10mA 2 5 of reading 10 digits Overload Protection 500mA 250V fuse 10A range unfused Measuring Voltage Drop 200mV RESISTANCE...

Page 9: ...nect the test leads from the meter 2 Remove the cover 3 Gently remove the old fuse and install the new fuse into the holder 4 Always use a fuse of the proper size and value 500mA 250V 5 Replace and se...

Page 10: ...suspected defect fault arises and return the product along with proof of purchase to the place of purchase or distributor for assessment Distributer contact details are available on the last page of...

Page 11: ...PAGE INTENTIONALLY LEFT BLANK...

Page 12: ...Distributed by Electus Distribution Pty Ltd 320 Victoria Rd Rydalmere NSW 2116 Australia Ph 1300 738 555 Int l 61 2 8832 3200 Fax 1300 738 500 www electusdistribution com au...

Reviews: