TESTER

DATA 

HOLD

2000 

DISPLAY 

COUNT

CAT III 

600V

LIFETIME

WARRANTY

Network  

Cable Tester

Digital Multimeter

SPECIALIST

Summary of Contents for XC5078

Page 1: ...LAN TESTER DATA HOLD 2000 DISPLAY COUNT CAT III 600V LIFETIME WARRANTY Network Cable Tester Digital Multimeter SPECIALIST ...

Page 2: ...PAGE INTENTIONALLY LEFT BLANK 2 ...

Page 3: ...taining this manual for ease of reference Improper use of this meter can cause damage shock injury or death Always remove the test leads before replacing the battery or fuses Before using the meter please inspect the condition of the test leads and the meter itself for any damage If damage is present please discontinue use Do not measure voltage if the voltage on the terminals exceeds 1000V above ...

Page 4: ...age Range 200mV 600V DC Current Range 2mA 200mA AC Current Range 2mA 200mA Resistance 200Ω 20MΩ Diode Test Yes Remote Terminator Yes LAN Tester Yes Base T Test Yes Modular Cable Test Yes Coaxial Cable Test Yes Remote Test Yes Max Hold Yes Data Hold Yes Autoranging Yes Auto Power Off Yes 4 ...

Page 5: ... rear of the multimeter Positive Input Jack Function Switch Test Button On Off Button LAN LED Display Auto Manual Ranging Button LCD Screen Jack RJ45 Jack RJ45 Remote Terminator COM Input Jack Mode Button Hold Button Max Hold Button 5 ...

Page 6: ... Hold Button Press the HOLD button to lock readings as displayed on the screen Press again to unlock Test Button In manual mode pressing the square Test button will advance testing to the next pin Mode The MODE button helps you to move through various operations with various icons displayed on screen It works in conjunction with the function switch to measure things like resistance continuity and ...

Page 7: ... 2000µA AC DC set the function switch to the mA position If the range of the measured current is not known select the higher range first then move to the lower range if necessary 2 Insert the black test lead into the negative COM input jack 3 Insert the red test lead into the positive V input jack 4 Press the mode button to select AC or DC measurement 5 Remove power from the circuit under test the...

Page 8: ...de button until appears on the screen 7 Touch the test probe tips to the circuit or wire you wish to test If the resistance is less than approximately 150Ω an audible signal will sound If the circuit is open the display will indicate OL RESISTANCE MEASUREMENT To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements Remov...

Page 9: ...nd LED scan or simply switch to Manual mode for pin by pin testing In Manual mode pressing the square Test button will advance testing to the next pin RJ11 MODULAR CABLE TEST Please follow directions for the UTP STP Cable Test and refer to the sample test results on page 9 for the correct LED pin out display COAXIAL CABLE TEST The center pin of BNC should be read on LED 2 As the coaxial cable has ...

Page 10: ...2 3 4 5 6 7 8 G 3 Short Pin 2 and Pin 3 are shorted 1 2 3 4 5 6 7 8 G 4 Miswire Pin 3 and Pin 6 are miswired RANGE ACCURACY 200mV 0 5 reading 3 digits 2V 1 0 reading 3 digits 20V 200V 600V MEASUREMENT SPECIFICATIONS The following guide is based on an environmental temperature of 18 28 C and humidity 80 DC VOLTAGE 10 ...

Page 11: ...its 20V 200V 1 5 reading 10 digits 600V AC VOLTAGE RANGE ACCURACY 200µA 1 5 reading 3 digits 2000µA 20mA 2 0 reading 3 digits 200mA DC CURRENT AC CURRENT RANGE ACCURACY 200µA 1 8 reading 8 digits 2000µA 20mA 2 5 reading 8 digits 200mA 11 ...

Page 12: ...nnect the test leads from the meter 2 Open the rear battery cover with a screwdriver 3 Remove the old battery and insert the new battery into the battery holder observing the correct polarity 4 Put the battery cover back in place and secure with the screws FUSE INSTALLATION 1 Turn the power off and disconnect the test leads from the meter 2 Open the rear cover with a screwdriver 3 Replace the fuse...

Page 13: ...idth 50 60Hz Operating Temperature 0 C 40 C Storage Temperature 10 C 50 C Operating Altitude 2000m max Power Supply 1 x 9V Battery 2 x AAA Batteries Dimensions 162 H x 74 5 W x 44 D mm Weight 308g including battery BOX CONTENTS 1 x Multimeter Lan Tester 1 x Lan Testing Remote Terminator 1 x Test Leads 1 x 9V Battery 2 x AAA Batteries 1 x Carry Case 1 x User Manual ...

Page 14: ...he suspected defect fault arises and return the product along with proof of purchase to the place of purchase or distributor for assessment Distributor contact details are available on the last page of this manual If the assessment concludes that the product is indeed defective faulty the product will either be repaired or replaced at no cost to you Our goods come with guarantees that cannot be ex...

Page 15: ...PAGE INTENTIONALLY LEFT BLANK 15 ...

Page 16: ...Distributed by Electus Distribution Pty Ltd 320 Victoria Rd Rydalmere NSW 2116 Australia www electusdistribution com au Made in China ...