RESISTANCE
RANGE
ACCURACY
200Ω
±(0.8% r 5 digits)
2kΩ
±(1.2% r 3 digits)
20kΩ
200kΩ
2MΩ
±(2.0% r 5 digits)
20MΩ
±(5.0% r 8 digits)
MAINTENANCE
BATTERY INSTALLATION
To avoid false readings, replace the battery as soon as the low battery
power indicator appears.
1) Turn power off and disconnect the test leads from the meter.
2) Open the rear battery cover with a screwdriver.
3) Remove the old battery and insert the new battery into the battery
holder, observing the correct polarity.
4) Put the battery cover back in place and secure with the screws.
FUSE INSTALLATION
1) Turn the power off and disconnect the test leads from the meter.
2) Open the rear cover with a screwdriver.
3) Replace the fuse with a 0.2A/250V fast acting fuse.
4) Put the cover back in place and secure with the screws.
12