Warning   

To avoid possible electric shock, injury, and 
damage to the Meter please follow these rules:

   

 

Before using the Meter, inspect the exterior 
casing. Do not use the Meter if it is visibly 
damaged or if it appears to be tampered with. 

 

Inspect the test leads for damaged insulation or 
exposed metal. Check the test leads for 
continuity. 

 

Do not apply more than the rated voltage, in any 
fashion to the Meter or terminals. 

 

The rotary switch should be placed in the correct 
position before measurement and should NOT be 
moved during measurement to prevent damage. 

 

When the Meter is working at an effective voltage 
over 60V in DC or 30V rms in AC take additional 
care due to increased danger of electric shock. 

 

Use the proper terminals, function, and range for 
your measurements. 

 

Do not use or store the Meter in a high-
temperature environment, do not expose to high 
levels of humidity, or near strong magnetic 
fields. The performance of the Meter may 
deteriorate in any of these harsh environments. 

 

Disconnect circuit power and discharge all high-
voltage capacitors before testing resistance, 
continuity, diodes or hFE. 

 

Replace the battery as soon as the battery 
indicator 

  appears.    A low battery will cause 

the Meter to produce inaccurate readings and 
could lead to damage and dangerous conditions. 

 

The Meter is suitable for dry location use only. 

 

Turn the Meter power off when it is not in use 
and take out the battery when not using for a 
long time to avoid battery leakage and damage 

Summary of Contents for PDM-711

Page 1: ...tps www ProTechTrader com User Guide ProTechTrader LARGE SCREEN DIGITAL MULTIMETER PDM 711 Please read this manual before using the multimeter Latest manual and more can be found on https www ProTechT...

Page 2: ...n DC or 30V rms in AC take additional care due to increased danger of electric shock Use the proper terminals function and range for your measurements Do not use or store the Meter in a high temperatu...

Page 3: ...rdg 3D 2000mV 1mV 20V 10mV 200V 100mV 1000V 1V 1 0 of rdg 5D 0 8 of rdg 5D OVERLOAD PROTECTION 220V rms AC for 200mV range and 1000V DC or 750V rms for all ranges AC VOLTAGE RANGE RESOLUTION ACCURACY...

Page 4: ...AD PROTECTION 500mA 250V fuse 10A range unfused MEASURING VOLTAGE DROP 200mV RESISTANCE RANGE RESOLUTION ACCURACY 200 0 1 1 0 of rdg 10D 2000 1 20K 10 200K 100 2000K 1K 1 0 of rdg 4D MAXIMUM OPEN CIRC...

Page 5: ...sired DC AC VOLTAGE position if the voltage to be measured is not known beforehand set switch to the highest range and reduce it until satisfactory reading is obtained AC 3 Connect test leads to devic...

Page 6: ...to desired DCA position 3 Connect test leads in series with the loaded current to be measured so that current may flow through the meter 4 Read current value on Digital Display Please Note The 10A fun...

Page 7: ...ower before measurement 4 Connect test leads to circuit being measured 5 Read resistance value on Digital Display DIODE MEASUREMENT 1 Red lead to V mA Black lead to COM 2 Set RANGE switch to position...

Page 8: ...lector leads Insert the leads into the proper holes of the hFE Socket on the front panel 3 The meter will display the hFE value while providing the base current 10 A and VCE2 8V CONTINUITY TEST Beep 1...

Page 9: ...instrument is warranted to be free from manufacturing defects in material and workmanship for one year Any instrument found defective within one year may be returned to the factory with transportation...

Page 10: ...electricity Approximately 4mA Product Size 129 x 70 x 29mm Product net weight 129g including battery Battery and Fuse Replacement Fuse will rarely need replacement Blown fuses are likely a result of o...

Reviews: