background image

 

 

-  8  -

 

© 201

https://www.ProTechTrader.com

 

 
TRANSISTOR (hFE) 

1. 

Set RANGE switch to the 
hFE position. 

2. 

Determine  whether  the 
transistor is PNP of NPN 
type  and  locate  the 
Emitter, 

Base 

and 

Collector leads. Insert the 
leads  into  the  proper 
holes  of  the  hFE  Socket 
on the front panel. 

3. 

The meter will display the 
hFE  value  while  providing  the  base  current 
10μA and V

CE

2.8V. 

 

 
CONTINUITY TEST (Beep) 

1. 

Red lead to “VΩmA”, Black 
lead to “COM”.

 

 

2. 

Set RANGE to “ ” position. 

3. 

Connect  test  leads  to  two 
points  of  circuit  to  be 
tested.  If  the  resistance  is 
lower  than  30Ω

±

20Ω,  the 

buzzer will sound. 

 
 
 

Summary of Contents for PDM-711

Page 1: ...tps www ProTechTrader com User Guide ProTechTrader LARGE SCREEN DIGITAL MULTIMETER PDM 711 Please read this manual before using the multimeter Latest manual and more can be found on https www ProTechT...

Page 2: ...n DC or 30V rms in AC take additional care due to increased danger of electric shock Use the proper terminals function and range for your measurements Do not use or store the Meter in a high temperatu...

Page 3: ...rdg 3D 2000mV 1mV 20V 10mV 200V 100mV 1000V 1V 1 0 of rdg 5D 0 8 of rdg 5D OVERLOAD PROTECTION 220V rms AC for 200mV range and 1000V DC or 750V rms for all ranges AC VOLTAGE RANGE RESOLUTION ACCURACY...

Page 4: ...AD PROTECTION 500mA 250V fuse 10A range unfused MEASURING VOLTAGE DROP 200mV RESISTANCE RANGE RESOLUTION ACCURACY 200 0 1 1 0 of rdg 10D 2000 1 20K 10 200K 100 2000K 1K 1 0 of rdg 4D MAXIMUM OPEN CIRC...

Page 5: ...sired DC AC VOLTAGE position if the voltage to be measured is not known beforehand set switch to the highest range and reduce it until satisfactory reading is obtained AC 3 Connect test leads to devic...

Page 6: ...to desired DCA position 3 Connect test leads in series with the loaded current to be measured so that current may flow through the meter 4 Read current value on Digital Display Please Note The 10A fun...

Page 7: ...ower before measurement 4 Connect test leads to circuit being measured 5 Read resistance value on Digital Display DIODE MEASUREMENT 1 Red lead to V mA Black lead to COM 2 Set RANGE switch to position...

Page 8: ...lector leads Insert the leads into the proper holes of the hFE Socket on the front panel 3 The meter will display the hFE value while providing the base current 10 A and VCE2 8V CONTINUITY TEST Beep 1...

Page 9: ...instrument is warranted to be free from manufacturing defects in material and workmanship for one year Any instrument found defective within one year may be returned to the factory with transportation...

Page 10: ...electricity Approximately 4mA Product Size 129 x 70 x 29mm Product net weight 129g including battery Battery and Fuse Replacement Fuse will rarely need replacement Blown fuses are likely a result of o...