2
230V AC
24V DC
2
TECHNICAL FEATURES
3. INSTALLATION
3.1 Standard Layout
Look at the beside layout and keep a safety distance of
500 mm each side.
The length of the boom will be accordingly,
but the concrete basement position is fixed.
3.2 Basement preparation
The concrete basement must be resisting (EN206 C25/30
minimum resistance). Basement plant has to be at least
400x500 and 600 mm deep.
Keep a projection of 20 mm from the ground floor to
ensure stability.
In any case the concrete work cannot impede to stud
the fixing screws
.
Do not forget wirings!
While preparing the
concrete basement keep a duct of the right
dimension to connect the main power and any
additional devices, if needed.
3.3 Fixing the barrier on ground
Drill the concrete basement, put the screws provided and fix the barrier body:
230V 50Hz
230V ac
200W
1,5A 230V
circa 6 secondi
da 1 a 60 sec.
6m
12Vdc, 8W max
da -20 a +50 °C
433,92 MHz
Main power:
Motor power supply:
Motor power:
Absorption max.:
Opening time:
Automatic closing:
Boom max. length:
Accessories:
Working temperature:
Radio frequency:
230V 50 Hz
24V dc
160W
1,2A 230V
circa 6 secondi
da 1 a 60 sec.
6m
24Vdc, 8W max
da -20 a +50 °C
433,92 MHz
Screws
Basement
Metal housing
4 anchor screws M16
Ground plate
Boom from 1,5 to 6m