IMPORTANT:

 To achieve optimum leverage for the gate opener and ensure long trouble free service, 

the gate opener needs to be installed within the following the ideal parameters to achieve 90 degree 
opening angle – measurements are taken from the pillar bracket to the gate bracket when gate is in 
closed position: 

 
 
 

 
 
 

Total A+B = 290mm  

 
 

 

 

 
 
 
 

 
 

     

    

              Total A+B = 390mm 
 
 
    

 

How to determine fixing dimensions 

 

FIG A  
 

In this scenario the maximum opening angle of the gates will be 90 degrees. The best approach is to 
put the fixing brackets at the measures indicated in the table on the next page. These quotes are 
calculated in order to obtain an average lateral speed that does not exceed 12m/minute and will 
open the gate to 90 degrees. 
 

FIG B 
 

In this scenario the gate can open with an angle greater than 90 degrees: 
 
Diamond 3Ti = 110 degrees maximum. 
Diamond 4Ti = 120 degrees maximum. 
 
The best approach is to put the fixing brackets at the measures indicated in the table on the next 
page to achieve initial 90 degrees open angle. To ensure the gate will open past 90 degrees, 
dimension A 

must

 be greater than dimension B, BUT dimension B must be reduced by the 

measurement value that dimension A was increased by. For example: 

90 degree angle (Diamond 3Ti) 

 

100 degree angle (Diamond 3Ti) 

Dimension A = 145mm 

 

 

Dimension A = 160mm 

Dimension B = 145mm 

 

 

Dimension B = 130mm 

Summary of Contents for Diamond 3Ti

Page 1: ...ds and Public Holidays Email support gatemotors co uk UK calls to this number are billed by the second and cost 1 02 per minute from a standard landline other networks charges may also apply IRISH cal...

Page 2: ...4Ti gate automation is designed for installation on a pull to open double leaf gate gates that open into the property The motors can be used on vinyl aluminium farm tube and wrought iron gates The Ki...

Page 3: ...the Motors to the Control Board 16 Installation Complete 18 Warranty 18 Obtaining Repairs Replacements 18 Kit Diamond 230v FAQ s 19 Will my gates still open in the winter when it is very cold and icy...

Page 4: ...ensure that the total system is safe for its intended use For The End User A WARNING To reduce the risk of injury or death A1 Read and follow all instructions Failure to meet the requirements set for...

Page 5: ...re installed they should be within sight of the gate yet located at least 3 Metres 10ft away from all moving parts of the gate Never install any access control device where a user will be tempted to r...

Page 6: ...ays turn power to the control board OFF before performing any maintenance Regularly grease the gate hinges and the motors triangular mounting bracket pivot point Clean the push pull ram arm tube with...

Page 7: ...Page 7 Kit Diamond 3Ti 4Ti Technical Specification Kit Diamond 3Ti 4Ti Dimensions...

Page 8: ...Page 8 NB Please quote above part numbers when enquiring about replacement model 3Ti 4Ti components from GateMotors...

Page 9: ...that are to be laid across your driveway Surge Protection A form of circuit breaker should be fitted between the house and the main gate to protect both the gate control board and the house main fuse...

Page 10: ...the gate only If hinges are stiff loosen with lubricating oil The gate must be able to move throughout its arc without binding or dragging on the ground The pillars posts must be secured into the grou...

Page 11: ...e table on the next page These quotes are calculated in order to obtain an average lateral speed that does not exceed 12m minute and will open the gate to 90 degrees FIG B In this scenario the gate ca...

Page 12: ...to left hand or right hand mounting illustrated left The bracket is fabricated from mild steel and has galvanised coating for durability in weathering The bracket is designed to be cut down using an...

Page 13: ...osen hole on the pillar bracket to the point of contact on your gate leaf where the gate leaf bracket is to be attached and mark accordingly A minimum of 30mm must be allowed from the edge of the pill...

Page 14: ...et S1 Slide the motor over the bracket taking care to align the fixing holes of the bracket and the motor located on the underside of the motor Support the weight of the motor arm so that the full wei...

Page 15: ...red on the gate engage the locking mechanism of the motor using the release key and remove the release key Ensure the release keys for the motors are kept in a secure place Motor Release Keys IMPORTAN...

Page 16: ...ontained within a suitable flexible conduit when buried under the driveway Armoured cable is available from GateMotors and is available in 25M 50M and 100M reels Using Fused Spur interim circuit break...

Page 17: ...each motor If a capacitor is not fitted the motor may physically vibrate gently and will fail to operate upon command The control board may display a communication fault code N1 N2 The capacitors are...

Page 18: ...Motors and does not cover repair or replacement of any goods or part thereof damaged by misuse moisture liquids proximity or exposure to heat and accident abuse non compliance with the installation an...

Page 19: ...ess of the transmitter button will open the gate and hold it open for a predetermined time adjustable to between five 90 seconds and then close it automatically This way no one needs to remember to sh...

Page 20: ...illars Blinker Warning Light A flashing blinker warning light can alert people to the operation of the gates The blinker light is compatible with of the Electric gate kits that we sell Oval blinker wi...

Page 21: ...ease let us know by email on sales gatemotors co uk Author G Opie Published September 2011 For more information on GateMotors full line of automatic gate openers and access controls visit our website...

Reviews: