3.7.3 CLOSING SAFETY EDGE 8K2 type
W
ire the CLOSING SAFETY EDGE 8K2 to terminals
5 - 9
on
JP5
terminal block
.
• If the safety edge meet any obstacle while the
gate is
CLOSING
,
the automation STOPS and
REVERSES.
• An obstacle detected by the safety edge while the
gate is
OPENING
does not cause any effect.
SAFETY EDGE 8K2 + PHOTOCELLS
Wire the 8K2 safety edge in series to the receiver photocell
(N.C. contact)
• If the safety edge meet any obstacle while the gate is
CLOSING
,
the automation STOPS and REVERSES.
•
An obstacle detected by the safety edge while the
gate is
OPENING
does not cause any effect.
3.7.4 OPENING Safety Edge 8K2 type
Wire the OPENING SAFETY EDGE 8K2 to terminals
6 - 9
on
JP5
terminal block.
Plea
se make sure that parameter in menu
is set on .
•
I
f the safety edge meet any obstacle while the
gate is
OPENING
,
the automation STOPS and
REVERSES for about 3
seconds.
• An obstacle detected by the safety edge while the
gate is
CLOSING
does not cause any effect.
SAFETY EDGE 8K2 + PHOTOCELLS
Wire the 8K2 safety edge in series to the receiver photocell
(N.C. contact)
Plea
se make sure that parameter in menu is
set on .
• If the safety edge meet any obstacle while the gate
is
OPENING
,
the automation STOPS and REVERSES for
about 3
seconds.
• An obstacle detected by the safety edge while the gate
is
CLOSING
does not cause any effect.
Please make sure that parameter in
menu is set on .
Please make sure that parameter in menu
is set on .