background image

1     2    3     4

ON          ECE

SW1

1     2    3     4

ON          ECE

SW1

1     2    3     4

ON          ECE

SW1

1     2    3     4

ON          ECE

SW1

1     2    3     4

ON          ECE

SW1

11 

                                                                                                                                                                                                                                                                                   Q80S_2014

J5

24V

ac

230V

ac

J5

J1

JP4

JP5

JP6

JP7

JP8

JP9

1      2      3      4      5      6      7       8     9     10    11

12    13    14    15   16    17

18       19       20

JP1

JP2

JP3

K3

K2

K4

22

21

T2

T1

U1

TR2

C8 C9

C21

C24

ALIM.

230Vac

5A

230Vac

1     2    3     4

ON          ECE

SW1

JP6

FLASH

24V ac

10    11

PROTECO S.r.l.

   

Via Neive, 77 - 12050 Castagnito (CN) ITALY     Tel. +39 0173 210111 - Fax +39 0173 210199      info@proteco.net - www.proteco.net

3.9.1 2ND RADIO CHANNEL settings

Note:  to use the MRX04 module as a 2nd radio channel, you need to save the corresponding radio code.

  

Please refer to RADIO menu, parameter           . 

Select the AUX module settings with SW1 dip-switch-block:

 

STABLE switch

Electric contact closes every time you press the remote control.

      

To select this mode, please set the dip-switches on the module as shown:

  

1= ON   2= OFF   3= OFF    

Dip-switch 4 is non influential.

BISTABLE switch – Toggle Mode

Electric contact closes or opens every time you press the remote control

.

To select this mode, please set the dip-switches on the module as shown:

  

1= OFF   2= ON   3= OFF   

 

Dip-switch 4 is non influential.

TIMER mode

Electric  contact  closes  when  you  press  the  remote  control  and  stays 

closed for 90 seconds. 

To select this mode, please set the dip-switches on the module as shown:

    

1= ON   2= ON   3= OFF   

 

Dip-switch 4 is non influential.

 

3.9.2 CONTROL LIGHT settings

You can use the MRX01 module to control an indicator light.

The  electric  contact  stays  closed,  so  the  light  stays  on,  during  all  the 

opening-closing cycle.

To select this mode, please set the dip-switches on the module as shown:  

1= OFF   2= OFF   3= ON   

  

Dip-switch 4 is non influential.

3.9.3 COURTESY LIGHT settings

You can also use the MRX01 module to control a courtesy light when the gate 

is operating. The electric contact closes since the gate starts operating till 90 

seconds after the gates stops.

To select this mode, please set the dip-switches on the module as shown:  

1= ON   2= OFF   3= ON   

  

Dip-switch 4 is non influential.

3.8 

BLINKER wiring

Y

ou can wire a flashing light (20W max) to 

10 - 11

 terminals on 

JP6

 

terminal block.

The flashing light will behave as follows:

• 

QUICK

 flashing 

→ the gate is 

OPENING

• 

SLOW

 flashing 

→ the gate is 

CLOSING

• 

STILL

 light on 

→ 

t

he gate is in PAUSE TIME before the 

 

   

 

    automatic closing

Note: 

You can select the kind of flashing light with             

parameter in the FUNCTIONS menu.

Additional

module

MRX01

3.9 

AUX/2ND RADIO CHANNEL module 

Driving 

slot

Plug  the  additional 

MRX01

  module  (optional)  into 

J5

 connector, 

p

lease pay attention to the module’s orientation as shown in the picture.

Before  setting  the  dip-switches

 SW1

  on  the  AUX  module, 

make sure that the control panel is disconnected from any 

power supply.

Summary of Contents for Q80S

Page 1: ...i Occupation function Pre Blinking function Additional radio channel optional module Built in radio receiver 433 92MHz 64 codes suitable for standard fix code transmitters or rolling code transmitters...

Page 2: ...settings 4 PROGRAMMING pag 12 4 1 Menu RADIO pag 12 4 2 PROGRAMMING menu pag 14 4 2 1 Selecting the PROGRAMMING MODE AUTOMATIC programming mode with OBSTACLE DETECTION SEQUENTIAL programming mode pag...

Page 3: ...nel must be performed with the control panel disconnected from the power supply Connect the control panel only to a power supply line equipped with safety grounding system Wiring settings and commissi...

Page 4: ...EASE or START command when not programming DECREASE or PEDESTRIAN START command when not programming DISPLAY segments display J1 radio module J5 plug for optional modules F2 230V fuse 5A FR1 24V fuse...

Page 5: ...050 Castagnito CN ITALY Tel 39 0173 210111 Fax 39 0173 210199 info proteco net www proteco net LIVE NEUTRAL EARTH CLOSE CAPACITOR FLASHING LIGTH 24V ac MAX 20w PEDESTRIAN BLACK STOP START COMMON CLOSI...

Page 6: ...IAN START command N O contact 4 NEUTRAL for controls JP5 PHOTOCELLS and SAFETY DEVICES 5 CLOSING PHOTOCELLS terminal N C contact 6 OPENING PHOTOCELLS terminal N C contact 7 Photocells RECEIVER power s...

Page 7: ...gate opening from left to right looking from inside the courtyard as shown in the drawing In case of gate opening from right to left please adjust parameter in accordingly to 01 see page 16 OUTSIDE I...

Page 8: ...RIAN START controls wiring Wire the PEDESTRIAN START control push button to 3 and 4 terminals on JP4 terminal block N O contact Additional PEDESTRIAN START controls push buttons can be wired in parall...

Page 9: ...area of the gate Note Should you need to temporary exclude the CLOSING PHOTOCELLS connections please set parameter in the ACCESSORIES menu to DISABLED 3 6 2 OPENING Photocells Power the OPENING PHOTOC...

Page 10: ...ause any effect 3 7 SAFETY EDGE wiring 3 7 2 OPENING Mechanical Safety Edge Wire the OPENING SAFETY EDGE to terminals 6 9 on JP5 terminal block If the safety edge meet any obstacle while the gate is O...

Page 11: ...ries to the receiver photocell N C contact If the safety edge meet any obstacle while the gate is CLOSING the automation STOPS and REVERSES An obstacle detected by the safety edge while the gate is OP...

Page 12: ...set the dip switches on the module as shown 1 ON 2 ON 3 OFF Dip switch 4 is non influential 3 9 2 CONTROL LIGHT settings You can use the MRX01 module to control an indicator light The electric contact...

Page 13: ...io codes on this control panel Press button and use to select menu then press button to enter the RADIO menu display will show Use buttons to scroll the lower level menu and select Saving a new remote...

Page 14: ...ultaneously press button on the control panel The display shows the radio code position 3 If the display shows It means that memory is full and no further code can be stored Repeat steps 1 and 2 to sa...

Page 15: ...procedure the gate will If open it start closing till the limit switch bracket meets the motor Then it opens till the opening limit position Stops and reverses till the fully closed position The contr...

Page 16: ...Before starting this programming procedure make sure that the TORQUE POWER is not set too high in that case please adjust parameter in menu to reduce it If the control panel is programmed using this p...

Page 17: ...n again till the display shows or wait the timeout 20 seconds to exit LIMIT SWICTHES mode 1 Use buttons to move inside the menu till the display shows 2 Press and hold button for about 5 seconds 3 Use...

Page 18: ...ve inside the menu till the display shows 2 Press button to confirm The display now shows the current torque power level for motor 3 Use buttons to change the motor torque power level 4 Press button t...

Page 19: ...IONS menu Use this menu to enable disable special settings function is ON function is OFF Press button and use to select menu then press button to enter the FUNCTIONS menu display will show Use button...

Page 20: ...e timeout 20 seconds to exit PHOTOCELLS TEST Function If this function is enabled the control panel performs a quick start up test with the photocells to make sure that they are in operation 1 Use but...

Page 21: ...osing To use this function you need to wire opening push button control to START terminals closing push button control to PEDESTRIAN START terminals 1 Use buttons to move inside the menu till the disp...

Page 22: ...S SWITCH Mode Use these settings to control the gate by a DEAD MAN S SWITCH The gate opens closes only if the button is hold pressed as soon as the button is released the gate stops opening closing Wi...

Page 23: ...this menu set the pause time for the Automatic Closing from 0 to 99 seconds 1 Use buttons to move inside the menu till the display shows 2 Press button to confirm 3 Use buttons to set the pause time...

Page 24: ...onfirm 3 Use buttons to reduce increase motor deceleration time 4 Press button to go back to the top level menus then press button again till the display shows or wait the timeout 20 seconds to exit O...

Page 25: ...ess button to enter the ACCESSORIES menu display will show Use buttons to scroll the lower level menus EMERGENCY STOP terminals 1 Use buttons to move inside the menu till the display shows 2 Press but...

Page 26: ...iving and transmitting photocell Wire the photocells or disabled corresponding parameter please refer to paragraph 3 6 1 Check transmitter and receiver position alignment Check and remove the obstacle...

Page 27: ...ith OBSTACLE DETECTION SEQUENTIAL Programming Procedure Reset to Default Settings for RAM openers OPENING DIRECTION of the motor LIMIT SWITCHES mode selection FORCE Menu TORQUE POWER adjustment OBSTAC...

Page 28: ...SABLED ENABLED WIRED DISABLED Opening photocells WIRED Safety Edge NC WIRED Safety Edge 8K2 WIRED Display MESSAGES Stand by Control Panel ready to work Closing PHOTOCELLS operating Opening PHOTOCELLS...

Page 29: ...chine under provisions of 2006 42 EC Machinery Directive It complies with the essential requirements of EEC Directives 2006 95 EC Low Voltage Directive 2004 108 EC Electromagnetic Compatibility Direct...